g1D=3.1128E-02g1B=8.4009E-02L1=300Q11D=71.38Q12D=69.46LVD11=150LVD12=150g2D=1.1963E-02g2B=3.9243E-02L2=300Q21D=85Q22D=85LVD21=150LVD22=150g3D=4.3091E-02g3B=1.2325E-01h1=0Q31D=72.31Q32D=76.32LVD31=150LVD32=150g4Dvmax=2.8216E-02g4Bvmax=9.3546E-02h2=0Q41D=67.27Q42D=69.29LVD41=150LVD42=150g5d=7.4497E-03g5B=2.8254E-02S=15Q51D=67.27Q52D=69.29LVD51=150LVD52=150TDmax=28332.20TBmax=14554.61PJD=120Q11B=255.91Q12B=254.9LVB11=150LVB12=150AD=333.31AB=49.46P’JD=10Q21B=294Q22B=294LVB21=150LVB22=150GJD=440GJB=30Q31B=260.36Q32B=173.9LVB31=150LVB32=150G'JD=520G'JB=40Q41B=245.77Q42B=256.91LVB41=150LVB42=150GD附加=2000GB附加=1500Q51B=245.77Q52B=256.91LVB51=150LVB52=150说明:T1=Q1*AL1为耐张杆一侧之水平档距,PJ为金具水平受力,GJ为金具垂直受力S/2S为线路转角度数,T1为耐张杆一侧导线之张力,T1为耐张杆一侧导线之张力横担T2=Q2*A1306.524673.863992.631996.32(N)49.539164.651996.32(N)634.48653.26(N)3992.633992.63653.26(N)9164.659164.65634.48634.484624.09(N)4540.56(N)G1B=g1B*AB*LVB11+GJB=G2D=g1D*AD*LVD12+GJD=荷载图:正常I耐张杆荷载计算:P1D=g4D(0.vmax)*AD*L1/2*COS(S/2)+T1D*SIN(S/2)+PJD=P2D=g4D(0.vmax)*AD*L2/2*COS(S/2)+T2D*SIN(S/2)+PJD=2)水平荷载:P(T取相应条件下的应力Q1乘以面积)1)垂直荷载:G1.正常情况I:最大风速、无冰、未断线Q为各种相应条件下的导、地线应力,如Q11D表示正常情况I下一侧导线的应力,Q12D为另一侧G1D=g1D*AD*LVD11+GJD=G2B=g1B*AB*LVB12+GJB=第1页,共20页2340.19(N)2333.67(N)△TD=(T1D-T2D)*COS(S/2)=634.48(N)△TB=(T1B-T2B)*COS(S/2)=49.53(N)2674.40(N)1908.802674.40(N)954.40(N)4211.67954.40(N)5348.800.00P1D=g5D(b.10)*AD*L1/2+T1D*SIN(S/2)+P'JD=4077.25(N)5348.808154.51P2D=g5D(b.10)*AD*L2/2+T2D*SIN(S/2)+P'JD=4077.25(N)0.005348.802105.84(N)8154.518154.512105.84(N)0.000.000.00(N)0.00(N)1996.32(N)1996.32(N)1306.52653.26(N)653.26(N)4239.732803.513992.63荷载图:正常II荷载图:正常III2)水平荷载:P(T取相应条件下的应力Q3乘以面积)G1B=g3B*AB*LVB21+G’JB=P1B=g4B(0.vmax)*AB*L1/2*COS(S/2)+T1B*SIN(S/2)=G1D=g1D*AD*LVD31+GJD=G2D=g1D*AD*LVD32+GJD=3)纵向荷载:△T3)纵向荷载:△TP2B=g4B(0.vmax)*AB*L2/2*COS(S/2)+T2B*SIN(S/2)=G1D=g3D*AD*LVD21+G’JD=G2D=g3D*AD*LVD22+G’JD=1)垂直荷载:G2.正常情况II:覆冰、相应风速气温、未断线G2B=g3B*AB*LVB22+G’JB=△TD=(T1D-T2D)*COS(S/2)=△TB=(T1B-T2B)*COS(S/2)=P2B=g5B(b.10)*AB*L2/2+T2B*SIN(S/2)=P1B=g5B(b.10)*AB*L1/2+T1B*SIN(S/2)=1)垂直荷载:G2)水平荷载:P(T取相应条件下的应力Q2乘以面积)G1B=g1B*AB*LVB31+GJB=G2B=g1B*AB*LVB32+GJB=3.正常情况III:最低气温、无冰、无风、未断线第2页,共20页3145.90(N)6466.253320.35(N)-1325.141680.84(N)3992.633992.631122.67(N)6466.256466.25-1325.14########-1325.14(N)4239.73(N)1306.523039.611996.32(N)4516.321996.32(N)2588.67653.26(N)19662.87653.26(N)3992.634516.32断线相:5177.332588.672520(N)19662.872588.67(N)P2D=P1D=2588.67(N)1519.81P2B=P1B=1519.81(N)19662.87(N)2183.261996.32(N)1996.32(N)1519.81653.26(N)########荷载图:断线II荷载图:断线I5.断线情况II:断任意一根地线、导线未断、无冰、无风G1B=g1B*AB*LVB41+GJB=G2B=g1B*AB*LVB42+GJB=4.断线情况I:同一档内断任意两相导线、地线未断、无冰、无风G1D=g1D*AD*LVD41+GJD=GD’=GJD+GD附加=1)垂直荷载:GP1D=T1D*SIN(S/2)=P1B=T1B*SIN(S/2)=P2B=T2B*SIN(S/2)=P2D=T2D*SIN(S/2)=正常相及断线相的未断线侧:△TD=(T1D-T2D)*COS(S/2)=△TB=(T1B-T2B)*COS(S/2)=3)纵向荷载:△T)1)垂直荷载:GG2D=g1D*AD*LVD42+GJD=P1D=0.7*TDmax*SIN(S/2)=P1B=0.8*TBmax*SIN(S/2)=3)纵向荷载:△T2)水平荷载:P(T取相应条件下的应力Q4乘以面积)正常相及断线相的未断线侧:G1D=g1D*AD*LVD51+GJD=△TD=0.7*TDmax*COS(S/2)=G2D=g1D*AD*LVD52+GJD=G1B=g1B*AB*LVB51+GJB=第3页,共20页653.26(N)5177.33断线相:1530(N)3992.632588.67(N)5177.335177.33P2D=P1D=2588.67(N)3992.633992.631519.81(N)P2B=P1B=1519.81(N)11544.08(N)△TB=0.8*TBmax*COS(S/2)=G2B=g1B*AB*LVB52+GJB=GB’=GJB+GB附加=2)水平荷载:P(T取相应条件下的应力Q5乘以面积)P1D=0.7*TDmax*SIN(S/2)=P1B=0.8*TBmax*SIN(S/2)=3)纵向荷载:△T第4页,共20页一、比载计算导线型号:LGJ-300/25G0D=1058TD=83410a1=1导线安全系数KD=2.944AD=333.31USCD=1.1a2=1最大风速Vmax=25dD=23.76uzD=1.11a3=0.85地线型号:GJ-50G0B=423.7TB=58233V1=10地线安全系数KB=4.001AB=49.46USCB=1.2V2=15覆冰厚度b=5dB=9uzB=1.15杆塔呼高=18a为风压(速)不均匀系数,V20m/s时a为1.0,20≤V30时a为0.85,30≤V35时a为0.75,V≥35时a为0.7UscD为电线风载体型系数,当电线覆冰(不论线径大小)或电线直径17mm时,USCD为1.2;当电线直径≥17mm时,USCD为1.1导线:地线:1.自重比载g11.自重比载g1g1(0.0)=3.11285E-02(MPa/m)g1(0.0)=8.40088E-02(MPa/m)2.冰层比载g22.冰层比载g2g2(b.0)=1.19625E-02(MPa/m)g2(b.0)=3.92425E-02(MPa/m)3.垂直总比载g33.垂直总比载g3g3(b.0)=4.30910E-02(MPa/m)g3(b.0)=1.23251E-01(MPa/m)4.风压比载g44.风压比载g41)外过电压、安装有风1)外过电压、安装有风g4(0.v1)=5.31133E-03(MPa/m)g4(0.v1)=1.53453E-02(MPa/m)2)内过电压2)内过电压g4(0.v2)=1.19505E-02(MPa/m)g4(0.v2)=3.45268E-02(MPa/m)3)最大风速3)最大风速g4(0.Vmax)=2.82165E-02(MPa/m)g4(0.Vmax)=8.15217E-02(MPa/m)5.覆冰风压比载g55.覆冰风压比载g5g5(b.10)=7.44965E-03(MPa/m)g5(b.10)=2.82541E-02(MPa/m)g4=9.80665/16*a*USCD*UZD*dD*V2/AD*10-3g5=9.80665/16*a*USCD*UZD*(dD+2b)*V2/AD*10-3g6=(g12+g42)0.5g7=(g32+g52)0.5G0D为导线单位质量,单位为Kg/Km;AD为导线截面积,单位mm2;b为覆冰厚度,单位mm;Td为计算拉断力,单位为N;KD为安全系数;g1=9.80665*G0D/AD*10-3g2=9.80665*0.9*3.1415926*b(b+dD)/AD*10-3g3=g1+g2dD为导线外径,单位mm;V为风速,单位为m/s;uZD为风压高度变化系数;6.无冰有风综合比载g66.无冰有风综合比载g6g6(0.v1)=3.15784E-02(MPa/m)g6(0.v1)=8.53988E-02(MPa/m)g6(0.v2)=3.33436E-02(MPa/m)g6(0.v2)=9.08272E-02(MPa/m)g6(0.vmax)=4.20137E-02(MPa/m)g6(0.vmax)=1.17061E-01(MPa/m)7.覆冰综合比载g77.覆冰综合比载g7g7(b.10)=4.37302E-02(MPa/m)g7(b.10)=1.26448E-01(MPa/m)三、气象条件工况名称最大风速最大覆冰最低气温外过电压内过电压断导线断地线温度(℃)15-5-101515000冰厚(mm)05000000风速(m/sec)2510010151000杆塔名称呼高(m)塔全高(m)正面根开A侧面根开B电压等级风载调整系数风速转角7718-1818.026.54.04.0351.0025.0015.000参数角度25.31.1821.00.352.056.602.191N18.81.0751.00.202.418.211.658N13.30.9621.00.202.4119.253.480N4.50.6801.00.202.4131.834.069N26.01.1920.80.302.162.470.746Y23.51.1540.80.3

1 / 20
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功