ICS29.240.01F20中国电力企业联合会标准T/CEC132—2017新型城镇化配电网建设改造成效评价技术规范Technicalevaluationspecificationforconstructionandreformeffectofdistributionnetworkfornewpatternurbanization2017-05-15发布2017-08-01实施中国电力企业联合会发布T/CEC132—2017I目次前言···································································································································································II1范围······························································································································································12规范性引用文件··········································································································································13术语和定义··················································································································································14总则······························································································································································25新型城镇化配电网分类原则·······················································································································26新型城镇化配电网建设改造成效评价指标体系························································································37评价方法与流程········································································································································10附录A(资料性附录)新型城镇化地区分类标准·······················································································11附录B(资料性附录)新型城镇化配电网建设成效评价指标权重分配表···············································12附录C(资料性附录)新型城镇化配电网建设成效评价指标计算方法···················································13编制说明··························································································································································25T/CEC132—2017II前言本标准依据GB/T1.1—2009《标准化工作导则第1部分:标准的结构和编写》给出的规则起草。本标准的附录A、B、C为资料性附录。本标准由中国电力企业联合会提出。本标准由国家电网公司归口。本标准主要起草单位:国网北京经济技术研究院、国网天津市电力公司、国网安徽省电力公司、国网湖南省电力公司、浙江华云电力工程设计咨询有限公司。本标准主要起草人:吴志力、杨卫红、郭玥、张红斌、张鹏飞、赵娟、杜振东、张章、伍济开、程啸、孙可、何红斌、迟福建、白桦、刘聪、叶彬、吴延峰、姜世公、王旭阳、朱勇、翁秉宇、张鸿雁、何禹清、石雪梅、叶斌。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。T/CEC132—20171新型城镇化配电网建设改造成效评价技术规范1范围本标准规定了新型城镇化配电网建设改造成效评价内容、评价指标及评价方法。本标准适用于县级及以下行政区域110(66)kV及以下新型城镇化配电网建设改造成效评价。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB/T156标准电压GB/T12325电能质量供电电压偏差GB/T29317电动汽车充换电设施术语GB50613城市配电网规划设计规范DL/T256城市电网供电安全标准DL/T599中低压配电网改造技术导则DL/T686电力网电能损耗计算导则DL/T836供电系统供电可靠性评价规程DL/T5118农村电力网规划设计导则DL/T5709配电自动化规划设计导则DL/T5729配电网规划设计技术导则3术语和定义下列术语和定义适用于本文件。3.1配电网distributionnetwork从电源侧(输电网、发电设施、分布式电源等)接受电能,并通过配电设施就地或逐级分配给各类用户的电力网络。其中,35kV~110kV电网为高压配电网,10(6、20)kV电网为中压配电网,220V/380V电网为低压配电网。3.2容载比capacity-loadratio某一供电区域、同一电压等级电网的公用变电设备总容量与对应的网供负荷的比值。容载比主要用于评估某一供电区域内35kV及以上电网的容量裕度,是配电网规划的宏观指标。3.3供电可靠性reliabilityofpowersupply配电网向用户持续供电的能力。3.4N-1停运firstcircuitoutage35kV~110kV电网中一台变压器或一条线路故障或计划退出运行;10kV线路中一个分段(包括架空线路的一个分段,电缆线路的一个环网单元或一段电缆进线本体)故障或计划退出运行。T/CEC132—201723.5配电自动化distributionautomation以一次网架和设备为基础,综合利用计算机技术、信息及通信等技术,实现对配电网的监测与控制,并通过与相关应用系统的信息集成,实现配电系统的科学管理。3.6分布式电源distributedgeneration接入35kV及以下电压等级、位于用户附近、以就地消纳为主的电源,包括同步发电机、异步发电机、变流器等类型。3.7指标属性indexattribute根据指标数值,反映指标的趋势走向,分为正向指标、逆向指标和适度指标。4总则4.1对新型城镇化配电网建设改造成效的综合评价,旨在全面客观反映新型城镇化背景下配电网建设改造工程建设水平和成效,提出结论和建议,指导新型城镇化配电网建设改造方向,推进新型城镇化配电网建设改造与管理提升工作。4.2从适应城镇化发展和用电差异化需求两个方面开展新型城镇化配电网建设改造成效评价,评价指标体系应能够反映配电网安全、可靠、经济、高效等基本特征,应与区域经济社会发展水平和可靠性需求相适应,充分考虑分布式电源大规模发展的需求,适应智能化发展趋势。4.3新型城镇化配电网建设改造成效应从电网结构、供电能力、供电质量、装备水平、智能化水平、适应性水平、经济性水平等方面进行评价。4.4新型城镇化配电网建设改造成效评价应采用定量与定性相结合的方式,各项指标均应对建设改造前后的情况统计分析,并形成评价报告。5新型城镇化配电网分类原则5.1新型城镇化地区分类5.1.1工业主导型此类城镇的工业基础较好,把发展工业和加快小城镇建设有机地结合起来,统一规划、连片开发、以工兴城、配套建设,逐步建成了新型的工业城镇,城镇内的人口多是乡镇企业工人,企业里的工人多是原来的村民,工农关系亲密、城乡关系密切。5.1.2商业贸易型此类城镇是传统的商品集散地,利用本地商品资源的优势,通过改善市场基础设施,拓宽交易范围,增大市场容量,逐步发展成为著名的区域性商业中心城镇或具有较大专业市场的城镇。5.1.3旅游开发型此类城镇依靠得天独厚的自然、人文条件,加强旅游、购物、娱乐、交通的配套设施建设,是旅游特色很强的新型城镇。5.1.4农业主导型此类城镇一般都有发展农业的优越条件,靠近大城市,通过发展特色种植养殖业、设施农业、观T/CEC132—20173光休闲农业来振兴经济。5.1.5综合型此类城镇产业特征不突出,无法归为以上4类中的任何一类。5.2新型城镇化配电网分类选取原则5.2.1新型城镇化地区分类应根据地方政府所提出的类型进行确定。5.2.2若地方政府未明确新型城镇化地区类型,则宜参见附录A确定新型城镇化地区类型。5.2.3对在明确所属新型城镇化地区类型的基础上,新型城镇化配电网还应根据DL/T5729确定供电区域划分等级。6新型城镇化配电网建设改造成效评价指标体系6.1电网结构6.1.1配电网标准化结构占比计量单位:%。指标释义:配电网标准化结构占比由10kV~110kV线路标准化结构占比经过加权平均而得出。某一电压等级线路标准化结构占比是指该电压等级采用标准结构的线路条数占该电压等级线路总条数的比例。计算方法:110(66)kV35kV0.3110(66)kV35kV10kV0.30.4100%10kV⎡⎢⎣⎤⎥⎦采用标准结构的线路条数采用标准结构的线路条数配电网标准化结构占比=×+线路总条数线路总条数采用标准结构的线路条数×+××线路总条数(1)指标属性:正向指标。6.1.210kV线路分段合理率计量单位:%。指标释义:分段数及每段配电变压器供电负荷均符合要求的10kV线路条数占10kV线路总条数的比例。计算方法:10kV10kV100%10kV合理分段的线路条数线路分段合理率=×线路总条数(2)指标属性:正向指标。6.1.310kV线路联络率计量单位:%。指标释义:存在联络的10kV线路条数占10kV线路总条数的比例。计算方法:10kV10kV100%10kV存在联络的线路条数线路联络率=×线路总条数(3)T/CEC132—20174指标属性:正向指标。6.1.410kV线路平均供电半径计量单位:km。指标释义:所有10kV线路供电半径的平均值。计算方法:10kV10kV10kV所有线路供电半径之和线路平均供电半径=线路总条数(4)指标属性:适度指标。6.1.5220/380V线路平均供电半径计量单位:m。指标释义:所有220V/380V线路供电半径的平均值。计算方法:220V/380V220V/380V220V/380V所有线路供电半径之和线路平均供电半径=线路总条数(5)指标属性:适度指标。6.2供电能力6.2.1110(66)kV容载比计量单位:无。指标释义:110(66)kV公用变电设备总容量(MVA)与110(66)kV电网年网供最大负荷(MW)的比值