ICS29.020F20/29准T/CEC196—2018超、特高压设备检修作业安全预警系统Safetyearly-warningsystemforEHVandUHVmaintenance2018-11-16发布2019-02-01实施中国电力企业联合会发布成品:210*297版心:166*238字数:45字*43行天35地24订24切20描图:7张T/CEC196—2018I目次前言···································································································································································II1范围······························································································································································12规范性引用文件··········································································································································13术语和定义··················································································································································14系统功能、分类及型号·······························································································································25要求······························································································································································36试验方法······················································································································································57检验规则····················································································································································108标志、包装、运输及贮存·························································································································11附录A(规范性附录)自检、通信功能试验······························································································13T/CEC196—2018II前言本标准依据GB/T1.1—2009《标准化工作导则第1部分:标准的结构和编写》给出的规则起草。本标准由中国电力企业联合会提出。本标准由全国架空线路标准化技术委员会线路运行分技术委员会(SAC/TC202/SC1)归口。本标准起草单位:国网安徽省电力有限公司检修分公司、国网安徽省电力有限公司、中国电力科学研究院有限公司、国网甘肃省电力公司检修公司。本标准起草人:曾德龙、李宏国、文志科、房贻广、张海峰、胡霁、李冀、张鹏飞、王新建、邵瑰玮、章海斌、郭振宇、孔晨华、陈怡、费烨、赵欢、胡宝华。本标准为首次发布。本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二条一号,100761)。T/CEC196—20181超、特高压设备检修作业安全预警系统1范围本标准规定了超、特高压设备检修作业安全预警系统的功能、分类、型号、要求、试验方法、检验规则、标志、包装、运输和贮存。本标准适用于超、特高压设备检修过程中保障作业安全的预警系统,其他电压等级可参照采用。2规范性引用文件下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。GB/T2423.1电工电子产品环境试验第2部分:试验方法试验A:低温GB/T2423.2电工电子产品环境试验第2部分:试验方法试验B:高温GB/T2423.3环境试验第2部分:试验方法试验Cab:恒定湿热试验GB/T2423.8电工电子产品环境试验第2部分:试验方法试验Ed:自由跌落GB/T2423.10电工电子产品环境试验第2部分:试验方法试验Fc:振动(正弦)GB/T4208外壳防护等级(IP代码)GB/T4857.23包装运输包装件基本试验第23部分:随机振动试验方法GB/T17626.2电磁兼容试验和测量技术静电放电抗扰度试验GB/T17626.3电磁兼容试验和测量技术射频电磁场辐射抗扰度试验GB/T17626.8电磁兼容试验和测量技术工频磁场抗扰度试验GB/T17626.9电磁兼容试验和测量技术脉冲磁场抗扰度试验GB26859电力安全工作规程电力线路部分GB26860电力安全工作规程发电厂和变电站电气部分3术语和定义下列术语和定义适用于本文件。3.1安全预警系统securityearly-warningsystem由定位基站、定位终端、移动显示装置、接地线挂接状态终端和通信模块组成,具备作业人员、安全围栏及接地线等定位数据收集、分析、显示与危险告警功能的系统。3.2定位基站positioningdatumstation由卫星信号接收装置及服务器组成。卫星信号接收装置布置在合适位置,方便接收卫星信号,发送数据至服务器进行处理,并通过无线通信方式向定位终端传输定位数据。3.3定位终端positioningterminal用于传输定位基站数据信号,并与自身所在位置的卫星信号进行联合解算,实现检修作业人员、安全围栏、作业工具的位置定位及数据通信的便携式装置。T/CEC196—201823.4接地线挂接状态终端groundingindicatorterminal将接地线挂接状态(包括挂接正常、挂错相线、脱落)通过无线方式发送至定位基站由显示终端进行显示的装置。3.5电子安全围栏safeelectronicfence在实体围栏上布置定位终端,根据定位终端的定位数据和布置顺序在服务器端形成作业区域,当作业人员跨越或移动安全围栏时,在服务器端及现场发出声光告警。4系统功能、分类及型号4.1系统功能4.1.1应具备作业人员、电子安全围栏及接地线等位置定位数据、图像数据的收集、分析、显示与告警功能。4.1.2应具有线路/变电站作业区域内三维场景模型或预留三维场景模型数据接入安全接口和功能扩展接口。4.1.3服务器端应具备安全区域、临近危险区域、危险区域规划功能,其中安全区域标记为绿色,临近危险区域标记为黄色,危险区域标记为红色。4.1.4在规划的区域作业时,作业人员与带电体之间的距离应符合GB26859、GB26860的相关规定。4.1.5系统网络及数据传输应符合本单位的信息安全要求。4.2系统分类根据使用环境不同分为线路型和变电(换流)站型,系统组成及部署见表1。表1系统组成及部署类型组成部分系统部署线路型定位基站、定位终端、移动显示装置、接地线挂接状态终端定位基站可部署在变电站内或另选合适位置,定位终端、移动显示装置、接地线挂接状态终端部署在现场变电(换流)站型定位基站、定位终端、接地线挂接状态终端、电子安全围栏定位基站部署在变电站内,定位终端、接地线挂接状态终端、电子安全围栏部署在现场4.3系统型号型号由产品的型式代号、类别代号(线路/变电站)、标称电压组成。安全预警系统的型式代号用AQYJ表示。表示方法:示例:安全预警系统类别为线路型,标称电压为1000kV。型号表示为AQYJ-XL-1000。T/CEC196—201835要求5.1卫星接收装置5.1.1一般要求5.1.1.1环境条件卫星接收装置在下列环境条件下应正常工作:a)环境温度:-25℃~+70℃;b)环境湿度:1%~100%;c)外壳防护等级:IP66。5.1.1.2外观结构卫星接收装置外观结构应符合下列规定:a)卫星接收装置表面应采取保护涂层或防腐措施,外表应光洁、均匀,不应有伤痕、毛刺等缺陷,标识应清晰。b)卫星接收装置内部电气及控制线路应排列整齐、固定牢靠、走向合理,便于安装、维护,各连接接口应采用醒目文字标识。5.1.2自检及通信功能要求卫星接收装置应具备自检及通信功能,可实现位置定位数据采集、通信功能自检。5.1.3机械性能要求卫星接收装置包装后应能承受GB/T4857.23规定的严酷水平Ⅱ级、试验时间180min运输振动试验。试验后卫星接收装置结构及功能正常。5.2定位终端5.2.1一般要求5.2.1.1环境要求定位终端在下列环境条件下应正常工作:a)环境温度:-25℃~+55℃(高寒地区按照-40℃~+55℃);b)环境湿度:≤85%;c)外壳防护等级:IP66。5.2.1.2外观结构定位终端外表应光洁、均匀,不应有伤痕、毛刺等缺陷,标识清晰,便于携带。5.2.2功能要求5.2.2.1定位模式支持北斗卫星导航系统和GPS定位模式。T/CEC196—201845.2.2.2通信模式支持公用通信、VPN通道或无线接力等通信模式。5.2.3性能要求5.2.3.1机械性能定位终端应进行的机械性能试验如下:a)整机振动。定位基站应能承受GB/T2423.10规定的振动试验。应满足下列试验条件:——试验波形:扫频正弦;——频率范围:10Hz~150Hz;——振动加速度:10m/s²。试验后定位终端结构及功能正常。b)运输振动。定位终端包装后应能承受GB/T4857.23规定的严酷水平Ⅱ级、试验时间180min运输振动试验。试验后定位终端结构及功能正常。c)抗跌落。定位终端可承受1.5m高度、6个方向自由跌落。5.2.3.2定位性能定位终端在水平方向定位精度应不低于20cm,垂直方向定位精度应不低于30cm。5.2.3.3电磁兼容性能定位终端电磁兼容性能要求如下:a)静电放电抗扰度。定位终端应进行GB/T17626.2规定的试验等级为4级的静电放电抗扰度试验,试验结果评定应达到A级。b)射频电磁场辐射抗扰度。定位终端应进行GB/T17626.3规定的试验等级为3级的射频电磁场辐射抗扰度试验,试验结果评定应达到A级。c)工频磁场抗扰度。定位终端应进行GB/T17626.8规定的试验等级为5级的工频磁场抗扰度试验,试验结果评定应达到A级。d)脉冲磁场抗扰度。定位终端应进行GB/T17626.9规定的试验等级为5级的脉冲磁场抗扰度试验,试验结果评定应达到A级。5.2.3.4连续工作时间作业人员随身携带的定位终端连续工作时间应不小于8h。5.3预警系统5.3.1告警5.3.1.1临近危险区