®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDowFILMTEC™RO/NF系统的运行DOWRESTRICTED-Forinternaluseonly2®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDowFILMTEC™膜系统的运行良好的运行和维护是维持系统长期成功运行的保证正确的运行维护是控制膜污染和结垢的前提DOWRESTRICTED-Forinternaluseonly3®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.安装元件2.启动3.停机4.性能监测5.清洗FILMTEC™膜系统的运行DOWRESTRICTED-Forinternaluseonly4®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow安装元件标准8英寸FILMTEC™膜元件1.检查上游管路及进水水质;2.填写膜元件安装记录表格;3.用水冲洗压力容器(PVs);4.用甘油润滑压力容器;5.安装压力容器浓水端端板;6.准备好膜元件;7.安装;8.调整轴向间隙,安装进水端端板;9.低压测试DOWRESTRICTED-Forinternaluseonly®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow给压力容器编号(示例)1-11-21-31-41-51-61-72-12-22-32-4A套DOWRESTRICTED-Forinternaluseonly®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow填写膜元件安装记录表格(示例)2-12-22-32-41-71-61-51-4…1-3…1-2……F1234561-1…654321膜元件在压力容器位置压力容器编号保管好安装记录表方便膜元件更换方便膜元件检查膜元件序列号DOWRESTRICTED-Forinternaluseonly7®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow压力容器的清洗与润滑海绵1.用水管冲洗压力容器;2.用海绵(水)清洗压力容器内壁;3.用海绵(50%甘油水溶液)润滑压力容器内壁安装元件DOWRESTRICTED-Forinternaluseonly8®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.安装止推环;2.装好元件适配器(元件与端板间的连接件,俗称手榴弹)和浓水端板止推环示例:安装浓水端端板止推环压力容器端板膜元件浓水端元件适配器水流安装元件DOWRESTRICTED-Forinternaluseonly9®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow•打开包装,小心取出膜元件并置于干净处(如水平地放在桌面上或竖直地搁在干净的地面上-硬纸板);•检查膜元件外观(尤其是产水中心管内部和盐水密封圈位置和方向是否正确);•标明安装示意图,记录膜元件的序列号;•润滑连接内接头(“O”型圈)和产水中心管内壁(可使用少量硅油*)*道康宁111;Molykote111膜元件的准备安装元件DOWRESTRICTED-Forinternaluseonly10®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow硅油润滑剂:DowCorning111orMolykote111使用其他润滑剂可能会导致运行问题将第一支元件(即压力容器末端最后一支,如编号#7)从进水端放入压力容器;将润滑后的连接内接头插入进水端元件产水中心管内第一支元件和连接件安装元件DOWRESTRICTED-Forinternaluseonly11®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow甘油/水(50%/50%)溶液食品级甘油检查盐水密封圈并润湿安装元件DOWRESTRICTED-Forinternaluseonly12®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow继续安装元件始终抬起元件以保持元件的水平!安装元件DOWRESTRICTED-Forinternaluseonly13®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow见培训录像:元件安装元件DOWRESTRICTED-Forinternaluseonly14®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.使用合适工具推入膜元件;2.安装调整间隙片以保证内接头与最前面和最后面的元件均能牢固的接触密封调整膜元件在压力容器内的轴向间隙ShimsShimsShimming进水端间隙调整片安装元件DOWRESTRICTED-Forinternaluseonly15®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.安装端板卡环2.安装弹簧片安装进水端端板(密封压力容器)安装元件12DOWRESTRICTED-Forinternaluseonly16®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow低压测试(针对海水淡化系统)安装原件DOWRESTRICTED-Forinternaluseonly17®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow低压测试目的:检查元件安装后是否存在任何泄露;方法:进水压力小于渗透压(5-6bar).若存在泄露,水将出现在产水侧;例外:在低压下,由于扩散作用将有一小部分水会渗透过膜,其量大约为100mL/min/PV.步骤:1.测试前用RO产水或高品质水*来冲洗;2.确保测试所使用的进水水质优良(大约SDI4);3.打开产水阀/产水取样阀;4.在低压下运行系统(~5bar);5.检查每个压力容器是否泄露;6.停机;7.检查泄露压力容器的泄露原因(如:卷曲或者损坏的”O”型圈,或未装适配器couplers)*电导率5,000S/cm,余氯为零,总细菌计数(TBC)50cfu/ml,SDI5.安装原件DOWRESTRICTED-Forinternaluseonly18®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow严重泄露如:遗漏盐水密封圈或未装适配器连接件中等/轻微泄露如:遗漏”O”型圈/盐水密封圈或”O”型圈损坏低压测试:检查泄露安装原件DOWRESTRICTED-Forinternaluseonly19®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.用水冲洗压力容器2.用甘油润滑压力容易3.安装压力容器浓水端端板(密封浓水端)4.准备元件5.安装元件6.调整轴向间隙,安装进水端端板(密封进水端)7.低压测试总结安装原件DOWRESTRICTED-Forinternaluseonly20®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDowFILMTEC™膜系统的运行1.安装元件2.启动3.停机4.性能监测5.清洗DOWRESTRICTED-Forinternaluseonly21®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow启动1.启动前的检查事项2.启动顺序DOWRESTRICTED-Forinternaluseonly22®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow预处理;膜单元;浊度和SDI;停机连锁;正确安装、校正和使用所有仪表;采取措施预防过高的产水背压(0.3bar,5psi);检查事项启动DOWRESTRICTED-Forinternaluseonly23®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow可对系统总进水、每段的进水、产水、浓水及总产水进行取样(安装了取样阀);压力容器牢固固定,与操作和清洗管线连接正确;泵和阀门已做好操作的准备(开启产水出水阀门,开启浓水控制阀门,调整高压泵出水阀或开启旁通调节阀,控制膜系统进水流量小于操作运行进水量的50%);监测仪器;水质分析仪器检查事项(续)启动DOWRESTRICTED-Forinternaluseonly24®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow启动来自预处理进水采样点产水采样点进水压力控制阀高压泵浓水控制阀DOWRESTRICTED-Forinternaluseonly25®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow启动顺序1.彻底冲洗原水预处理部分,冲掉杂质和其他污染物;2.检查所有阀门并保证所有设置正确;3.低压冲洗排气;4.检查泄露;5.产水阀和浓水控制阀处于打开位置;6.进水控制阀接近全关;7.启动高压泵;8.缓慢打开进水控制阀;9.缓慢关闭浓水控制阀,调节至设计回收率;10.调节进水和浓水控制阀达到设计产水量;11.检查所有化学药剂投加量是否与设计值一致,检查LSI指数或S&DSI指数;12.让系统连续运行1小时;13.记录所有运行参数;14.检查每个压力容器的产水电导;15.取水样分析;16.比较设计参数与系统实际运行参数;17.待系统稳定后将系统转换成自动运行模式;18.在连续操作48小时后,查看所有系统性能参数;此时的系统运行参数能作为系统性能变化的基准启动DOWRESTRICTED-Forinternaluseonly26®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow1.安装元件2.启动3.停机4.性能监测5.清洗FILMTEC™膜系统的运行DOWRESTRICTED-Forinternaluseonly27®™TrademarkofTheDowChemicalCompany(“Dow”)oranaffiliatedcompanyofDow停机停机后注意事项必须用产水或高品质水低压冲洗膜系统3分钟(~3-4bar,Cf=Cb)冲洗水水质要求•首选膜系统产水•不含用于预处理的化学药品(不包括S