CEDIPerformanceProjection-SystemSummaryProductFlowRate150M3/hModuleTypeLXM30X/LXM30ZNumberofModules34FlowPerModule4.4M3/hConductivity@25¡ãC0.79uS/cmFeedwaterconductivityequivalent,includingCO20.79uS/cmTotalExchangeableAnions(TEA)0.7ppmasCaCO3SystemRecovery95.00%ProductResistivity16.66MegOhm-cmSaltRejection92.44%PressureDrop3.08barWaterAnalysisSpeciesInlet,ppmasionOutlet,ppbasionConcentrate,ppmasionNH4K0.00710.1Na0.182143.6Mg0.00110Ca0.00110SrBaFeCuAlMnCO3HCO30.477369.5NO3Cl0.01310.3FSO4SiO2CO2pH8.3Temp.C15Thisprojectionisanestimateofperformanceandnotaguarantee.Caution:CalculatedpHvaluedoesnotagreewithinputvalue.Feedtotalchlorinelevelmustbelessthan0.02ppmasCl2atCEDIinlet.Start/stopsystemsrequireROpre-servicepermeateflushtodrain.Maximuminletpressureis100psig(6.9bar).Themaximumpossiblerecoveryforallmodulesis95%.Ifthehardnessisgreaterthan0.2ppmasCaCO3,orSilicagreaterthan0.5ppmassuch,themaximumrecoveryis90%.However,theminimumrejectflowis0.14m3/hr(0.62gpm)permodule,whichmaylimittheoverallrecovery.Pleasenotethateffluentsilicacannotbeguaranteediftheinfluentisgreaterthan0.5ppmassilica.Requiredpowersupplyis400VDC/6ampspermodule.Thepowersupplyboardpartnumberis:IP-400VPCB1/2IP-PROv1.85/9/2011CEDIPerformanceProjection-PowerConsumptionLXM30X/LXM30Z34Modules0.038kW/module0.0082kWh/M3Requiredpowersupplyis400VDC,6ampspermodule.Thepowersupplyboardpartnumberis:IP-400VPCBTotalFeed157.89M3/h0.79uS/cm(0.79uS/cmFCE)0ppmasionSiO20ppmasionCO215C3.08barTotalProduct150M3/h16.66MegOhm-cm5ppbSiO20barTotalReject7.89M3/h**Thesenumbersareestimatesonly.Powermayhavetobeadjustedbasedonspecificproductqualitytargets.2/2IP-PROv1.85/9/2011