LAR-ELOX100-OPERATIONMANUALElox100On-line,AcceleratedCODAnalyzer操作说明书北京比尔泰克公司BIOTECHCO.,TEL:021-549993011LAR-ELOX100-OPERATIONMANUAL目录1.ELOX100操作原理1.1COD分析……………………………………………………………………………11.2ELOX100正视图……………………………………………………………………21.3EXOX100俯视图……………………………………………………………………21.4EXOX100管路图……………………………………………………………………31.5EXOX100电极………………………………………………………………………41.6EXOX100键盘………………………………………………………………………52.安装及开机准备2.1安全操作注意事项及说明……………………………………………………………62.2供应件…………………………………………………………………………………62.3.1周围条件……………………………………………………………………………62.3.2电源…………………………………………………………………………………62.3.3样品供应……………………………………………………………………………72.3.4排水…………………………………………………………………………………82.3.5软水…………………………………………………………………………………82.4.1ELOX100壁挂式安装………………………………………………………………82.4.2电极安装……………………………………………………………………………92.4.3管路安装……………………………………………………………………………102.4.3.1夹挤阀管路安装………………………………………………………………102.4.3.2蠕动泵管路安装………………………………………………………………112.4.4化学试剂……………………………………………………………………………112.4.5水力连接……………………………………………………………………………122.4.6电气连接(模拟输出,继电器,数字输入线)……………………………………123.ELOX100是如何工作的3.1分析仪的启动……………………………………………………………………………163.1.1操作软件的启动………………………………………………………………………163.1.2操作软件的总体评价………………………………………………………………163.1.3完整的帮助系统………………………………………………………………………193.1.4填充管路系统…………………………………………………………………………203.2.1测量参数显示…………………………………………………………………………213.2.2系统设定………………………………………………………………………………213.2.2.1测量频率…………………………………………………………………………223.2.2.2校正/测量量程…………………………………………………………………233.2.2.3试剂消耗指示…………………………………………………………………233.2.2.4报警设点…………………………………………………………………………243.2.2.5保存操作参数…………………………………………………………………24BIOTECHCO.,TEL:021-549993012LAR-ELOX100-OPERATIONMANUAL3.3.1模拟输出………………………………………………………………………………253.3.1.2检查模拟输出……………………………………………………………………273.3.2设置并检查继电器(可选择的附件)…………………………………………………283.3.2.1设置继电器………………………………………………………………………283.3.2.2检查继电器………………………………………………………………………303.4设置日期和时间………………………………………………………………………313.5校正ELOX100……………………………………………………………………………323.6运行模式…….……………………………………………………………………………333.6.1要求……………………………………………………………………………………333.6.2启动运行模式…………………………………………………………………………333.6.3测量数据库……………………………………………………………………………343.6.4测量过程的有关事项…………………………………………………………………353.6.5状态屏…………………………………………………………………………………353.6.5.1显示当前操作参数………………………………………………………………363.6.5.2在运行模式中检查自动校正……………………………………………………373.6.6以表格形式检索数据………………………………………………………………373.6.7在运行模式下操作内部数据库………………………………………………………393.6.8结束运行模式…………………………………………………………………………393.7.1实验室测量的采样……………………………………………………………………403.7.2输入水流名称…………………………………………………………………………423.7.3输入名称和单位………………………………………………………………………423.7.4输入实验室数据………………………………………………………………………423.7.4.1自动线性模拟……………………………………………………………………433.7.4.2以零截距拟合直线………………………………………………………………443.7.4.3拟合参数的外部确定……………………………………………………………443.7.4.4复合线……………………………………………………………………………453.8.1每周维护和检查………………………………………………………………………453.8.2填充管路系统…………………………………………………………………………453.8.3填充测量槽……………………………………………………………………………453.8.4排空测量槽……………………………………………………………………………453.8.5校正ELOX100………………………………………………………………………453.9.1内部数据库操作………………………………………………………………………463.9.1.1选择测量数据文件………………………………………………………………463.9.1.2以表格方式显示数据文件………………………………………………………463.9.2操作人员记录…………………………………………………………………………483.9.3检查校正功能…………………………………………………………………………484.ELOX100的维护4.1启动运行模式……………………………………………………………………………50BIOTECHCO.,TEL:021-549993013LAR-ELOX100-OPERATIONMANUAL4.2短期关机后启动运行模…………………………………………………………………504.3每周维护…………………………………………………………………………………504.4每月维护…………………………………………………………………………………514.5每季度维护………………………………………………………………………………514.6长期关机程序……………………………………………………………………………514.7维护任务描述(以字母为序)…………………………………………………………514.8备用件和维护件…………………………………………………………………………595.故障分析……………………………………………………………………………………..606.数据分析6.0ELOX100的优异点………………………………………………………………………616.1水中有机成分的电化学测量……………………………………………………………616.2ELOX100测量系统………………………………………………………………………617.技术信息7.1技术数据…………………………………………………………………………………62BIOTECHCO.,TEL:021-549993014LAR-ELOX100-OPERATIONMANUAL1.ELOX100的操作原理1.1COD分析ELOX100COD分析仪可以容易、自动的检测有机物含量。ELOX100具有样品处理简单和维护成本低的优点。使用电化学测量原理不需额外提供氧化剂。使用ELOX100非常容易。仪器提供的菜单操作软件可以控制仪器的所有功能。在水和污水的测试中,由于无数单种物质的测定需要太多精力,因而综合参数的测定是非常重要的。在综合参数中,有机物的处理参数,如COD或TOC,使用非常频繁。ELOX100完善了当前常用的COD或TOC测量方法,并可在不同量程的应用场合替代原方法。氧化性测定,即ELOX100使用电化学测有机物含量,比传统的COD或TOC分析方法更容易。不需要有毒化学物质和高能耗,并且测量时间只需几分钟。电化学法的优异处使在线测量成为可能,测量结果总与当前水样相关。电化学法的测量原理为:在过电压条件下,电极将电解氧气产生羟基。这一特殊现象在过氧化铅层中亦可见到。羟基的氧化电位比其他氧化剂(如O3或KCrO4)高。因而可以氧化难以氧化的水中组份。待测溶液中的有机物消耗电极周围的羟基,新羟基的形成将在电极系统中产生电流。由于氧化电极(工作电极)的电位保持恒定,则每秒电负荷与有机物浓度和它们在氧化电极的氧化剂消耗量相关。ELOX100的主元件为测量槽。槽中有用于测量样品电流的电极组件,用于样品传输样品的泵、阀们、管道以及用于控制样品传送、显示结果、与外围设备通讯的内部计算机(0/4—20mA模拟输出,继电器(可选))。BIOTECHCO.,TEL:021-549993015LAR-ELOX100-OPERATIONMANUAL1.2ELOX100正视图1.3ELOX100俯视图BIOTECHCO.,TEL:021-549993016LAR-ELOX100-OPERATIONMANUAL1.4ELOX100管路图BIOTECHCO.,TEL:021-549993017LAR-ELOX100-OPERATIONMANUAL1.5ELOX100电极1.计数电极2.氧化电极(工作电极)3.参比电极231BIOTECHCO.,TEL:021-549993018LAR-ELOX100-OPERATIONMANUAL1.6ELOX100键盘二次功能键:切换到以红色书写的功能确认键:Enter激活所选菜单和用于确认输入取消键:ESC取消当前动作,返回上一级菜单,忽略输入。数字键:0…9选择菜单项和向ELOX100输入数据。功能键F1—F5和Shift+F6-F10:F1…F10功能键用于激活软件的特殊功能。F1具有帮助功能。按F1之后,将显示当前软件项目的解释。光标上/下键:↑,↓选择上/下一菜单项,或选择列表的下一项目光标左/右键:←,→在输入域内左右移动退格键:←删除光标前的数字Shift+PgUp/PgDw:PgUp/PgDw跳至列表的上/下屏Shift+开端/末尾:Home/End跳至列表的开端/末尾Shift+删除:Del删除光标所在位置的字符Shift+空格:Space产生一个空格Shitf+插入:Ins从插入模式转至修改模式,或从修改模式转至插入模式。在修