filtrax中文说明书

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

1FiltraxTM超滤系统使用手册©哈希公司HachCompany,2002.版权所有2目录安全警告...................................................................................................................3规格参数.....................................................................................................................4第一部分总体描述1.1应用.....................................................................................................................51.2操作原理.............................................................................................................51.3打开仪器包装…………………………………………………………………………………51.4显示屏和键盘......................................................................................................6安装第二部分安装...........................................................................................................92.1客户提供的设备………………………………………………………………………………92.2安装环境...…………………………………………………………………………………..92.3固定Filtrax系统……………………………………………………………………………….92.3.1将控制器固定在一个杆子上................................................................................112.3.2把控制器固定在墙上...................................................….....................................112.4将膜斗固定在水池中....................................……............................................112.5管道连接...…………………………………………………………………………………132.5.1吸入软管安装..................................................................…................................142.5.2样品运输软管安装....….......................................................................................152.5.3安装控制器中的管线...........................................................................................172.6连接到在线测量仪器...................................................…...........................................182.7电路连接.....…………………………………….………………………………………….192.7.1静电释放(EDS).……….......................................................................................202.7.2给仪器接电源线..................................................................................................202.7.3为吸入管加热系统接电源线...............................................................................232.7.4为样品管加热系统接电源线........……................................................................242.7.5为警报器接电源线………………………………………………………………...242.8过滤器模块安装和启动....................….......................................................................242.9启动……………………………………………………………………............................25操作第三部分菜单系统...................…....................................................................................293.1键盘描述.......………………………………………………………………………………293.2菜单.……………………………………………………………………………….............293.2.1主菜单.…………………….……………………………………………………….....303.2.2设备数据(DeviceData)菜单………………………………………………………...303.2.3信号(Signal)菜单....………………………………………………………………….313.2.4操作计数器(Op.Coounters)菜单…………………………………………………….313.2.5服务(Service)菜单....………………………………………..…………………………3133.2.5.1元件测试菜.单….............................................................................…............32维护第四部分维护………………………………………………………………………………....354.1维护程序…………………………………………………….……………………………...354.2更换计量管线............................................................................................................354.3更换空气过滤器…………………………………………………………………………….364.4系统清洁..…………………………………………………………………………………..374.5更换保险丝...…………………………………………………………………………….....384.6清洁仪器外壳............................................................................................................39第五部分故障发现和解决…………………………………………………………………..….41更换部件.……………………………………………………………………………………….47安全警告4在打开仪器包装,安装和使用仪器之前,请完整阅读本说明书。对所有特别提醒的地方尤其需要注意,否则可能引起对仪器的严重破坏或对操作人员的伤害。不要在手册提示以外的情况下使用本仪器,以免对仪器的保护失效。阅读所有仪器上的标签。否则可能引起对仪器的严重破坏以及操作人员的伤害。危险信息使用本手册使用不同的词语(危险、警告、注意)来指示情况危险程度由重到轻。危险:此符号表示有潜在或者明显的危险情况,如果发生有可能造成死亡或者严重伤害。警告:此符号表示潜在的危险情况,如果发生有可能引起中等程度或者轻微的伤害。注意:表示需要额外强调的信息。警告标签阅读所有仪器上的标签。否则可能引起对仪器的严重破坏以及操作人员的伤害。请参阅使用手册以进行安全操作。可能带电,必须专业人员才可以打开。有保险丝或者电流限制。可能较热,请小心接触。仪器对静电比较敏感,请小心接触。化学品危险,只有专业人员才能进行化学品的运输和相关仪器维护。需要戴防护镜。必须接地。规格参数5规格参数可能未经通知就更改。电源供应100-240V,50/60Hz安装目录II样品进入管加热停止电涌(-20°C)加热连续进行(-20℃)2m150Vac450Vac200Vac650Vac(115V)300Vac10m150Vac950Vac(230V)300Vac1000Vac(230V)400Vac所需电源20m150Vac1500Vac(230V)400Vac样品流速大概900mL/h,昀多连接3个仪器错误报警继电器无电位继电器(230v,昀大3A)警告继电器无电位继电器(230v,昀大3A)输出(使用屏蔽线管)服务界面RS232吸入管5m(加热)样品运输管2m(不加热)管线长度样品运输管10m(加热);20m(加热)检查频率大概1小时/月样品温度5-40℃适宜操作温度-20-40℃储存温度需要相对湿度需要外壳级别IP55控制单元22kg49lb.带5m吸样管的的模斗9kg20lb.样品管,10m5kg11lb.样品管,20m10kg22lb.重量(大概)样品管,2m(可选)5kg11lb.控制单元(W×H×D)430×530×220cm17×21×9in.尺寸(大概)膜斗(W×H×D)92×500×340cm4×20×14in.昀大吸入压头3m(9ft.)昀大水样运输压头7m(21ft.)第一部分总体描述61.1应用FiltraxTM系统是用来对废水处理厂的曝气池和昀终沉淀池的出水进行过滤和输送。它可以为它后续的测量仪器提供不含固体的水样。如果在其他方面使用这个仪器,比如污水处理厂废水进水或者是初次沉淀池出水,则有可能因为过多的油脂含量影响仪器使用。因此,在这些方面使用前,必须先进行实验性安装。1.2操作原则Filtrax样品萃取和准备系统包括三个组件:控制单元,膜和膜斗,样品输送管线。膜斗浸没在液面以下(可以使用可选的墙上固定工具包,Cat.No.LZX414.54.00000)。模斗内有2个过滤器,每个过滤器上可安装过滤膜。废水水样通过膜的过滤进入管线系统。控制单元中的两个定量泵把通过膜的水样带入5m长的加热的采样管,进入控制单元。然后根据传输距离的远近,水样经过2m(10m或者20m)送样管进入在线测量装置。内置的空气清洁装置避免膜受到固体物质的污染,节省维护时间和成本。1.3打开仪器包装将仪器从运输包装中取出,并检查有无损坏。确定下表所列的试剂、连接/安装的硬件和试剂管没有缺少。如果有损坏的情况发生,或者部件不齐全,请和客户服务中心联系。美国的用户,请拨打免费电话1-800-227-4224。表1标准配置

1 / 31
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功