110kV立塔架线施工方案

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-1-鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案福建省亿力电力建设有限公司二O一六年四月鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-2-批准:年月日审核:年月日编写:年月日鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-3-目录一、工程概况:········································································-1-(一)线路有关情况说明····························································-1-(二)主要交叉跨越··································································-2-(三)、杆塔明细······································································-4-(四)、本工程异动···································································-5-二、现场人员布置安排如下表:···················································-8-三、施工工艺流程:································································-10-(一)、工作准备····································································-10-(二)、50t吊车组立钢管杆方案················································-11-(三)、导线架设及附件安装·····················································-19-(四)附件安装······································································-22-(五)OPGW光缆架设·······························································-23-(六)、施工危险点分析及控制措施:·········································-25-(七)、安全事故事件应急预案:···············································-31-附表一、杆塔分节重量表··························································-35-鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-1-新垵变T接110kV鼎美~正东ⅠⅡ回线路工程(立塔架线施工方案)一、工程概况:(一)线路有关情况说明本工程线路起自110kV芸伟变构架,止于已建110kV鼎康Ⅰ回#9塔、110kV鼎康Ⅱ回#9塔。架空线路全长1.919km,其中双回架空线路长1.84km,单回路架空线路长97m。新建线路110kV芸伟变构架至新建#14塔采用同塔双回架设,鼎芸Ⅱ回从#14塔引下,改为电缆敷设至已建的鼎康Ⅱ回#9塔,鼎芸Ⅰ回从新建#14塔架空接至已建的鼎康Ⅰ回#9塔。本工程新建铁塔共14基,其中直线塔2基,耐张塔12基,均为钢管杆。本工程全线导线采用JLHA3-335中强度全铝合金导线,全线安全系数不低于7.0。本工程芸伟变构架~新建#14塔段地线为双OPGW复合光纤地线,两根地线均直接接地;新建#14塔~已建鼎康Ⅰ回#9塔段地线一根为OPGW复合光纤地线另一根为JLB40-80良导体地线,两根地线均直接接地。本工程以芸伟变往已建鼎康Ⅰ回#9塔为线路前进方向,OPGW挂在塔头右侧地线架上,良导体挂在塔头左侧地线架上。本工程OPGW光缆接至鼎美变构架,因此需将鼎康Ⅰ回、鼎康Ⅱ回原良导体地线更换为OPGW光缆。鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-2-2、新建部分本工程新立钢管杆14基、新架设2km导线。3、主要交叉跨越(二)主要交叉跨越跨10kV线路2处跨通讯线2处跨公路村道6处跨树林40处(60m为一处)鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-3-鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-4-(三)、杆塔明细3.1、本工程采用的杆塔,其杆型数量见下表:杆塔型式呼称高数量1GGD7-SJG42131GGD7-SJG22421GGD7-SJG12151GGD7-SJG12421GGD7-SZG12123.2、杆塔位明细表杆号塔型档距芸伟变构架21#11GGD7-SJG4-21132#21GGD7-SJG1-21109#31GGD7-SJG4-21274#41GGD7-SZG1-21#51GGD7-SJG1-21237#61GGD7-SZG1-21#71GGD7-SJG4-2191#81GGD7-SJG2-24189#91GGD7-SJG1-21181#101GGD7-SJG1-21147#111GGD7-SJG2-24158#121GGD7-SJG1-24145鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-5-#131GGD7-SJG1-21156#141GGD7-SJG1-2477鼎康#9(四)、本工程异动1、异动前后电气总接线示意图110kV鼎板Ⅱ回110kV鼎康Ⅱ回110kV鼎塑Ⅰ回110kV鼎塑Ⅱ回104间隔103间隔110kV长塑变110kV鼎板Ⅰ回110kV鼎板Ⅱ回110kV鼎板Ⅱ回110kV鼎康Ⅱ回110kV鼎板Ⅰ回110kV鼎康Ⅰ回199间隔111间隔198间隔197间隔104间隔103间隔110kV板带变110kV鼎康Ⅰ回110kV鼎板Ⅰ回220kV鼎美变#4110kV鼎塑Ⅱ回110kV鼎塑Ⅰ回103间隔104间隔110kV芸伟变110kV鼎芸Ⅰ回110kV鼎芸Ⅱ回#9#9#9#9异动前电气接线图鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-6-110kV鼎芸Ⅱ回110kV鼎芸Ⅰ回110kV芸伟变104间隔103间隔110kV鼎塑Ⅰ回110kV鼎塑Ⅱ回#4220kV鼎美变110kV鼎板Ⅰ回110kV鼎芸Ⅰ回110kV板带变103间隔104间隔197间隔198间隔111间隔199间隔110kV鼎康Ⅰ回110kV鼎板Ⅰ回110kV鼎康Ⅱ回110kV鼎板Ⅱ回110kV鼎板Ⅱ回110kV鼎板Ⅰ回110kV长塑变103间隔104间隔110kV鼎塑Ⅱ回110kV鼎塑Ⅰ回110kV鼎芸Ⅱ回110kV鼎板Ⅱ回异动后电气接线图2、异动前后地理总接线示意图鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-7-异动前地理接线图110kV鼎塑Ⅰ回110kV鼎塑Ⅱ回104间隔103间隔110kV长塑变引线未搭接引线未搭接构架110kV鼎板Ⅰ回110kV鼎板Ⅱ回110kV鼎板Ⅱ回110kV鼎康Ⅱ回110kV鼎板Ⅰ回110kV鼎康Ⅰ回199间隔111间隔198间隔197间隔110kV鼎板Ⅱ回#1#1#8#8#9#9#10#17#17甲#17甲#17#10#9#9#8#8#1#1104间隔103间隔110kV板带变110kV鼎板Ⅱ回(右线)110kV鼎康Ⅰ回110kV鼎康Ⅱ回110kV鼎板Ⅰ回110kV鼎板Ⅰ回(左线)220kV鼎美变#4#4#4#4#1#1#2#2110kV鼎塑Ⅱ回110kV鼎塑Ⅰ回(右线)(左线)(右线)(左线)(右线)(左线)鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-8-异动后地理接线图110kV鼎芸Ⅱ回110kV鼎芸Ⅰ回#10110kV芸伟变#23#23#10104间隔103间隔(左线)(右线)(左线)(右线)(左线)(右线)110kV鼎塑Ⅰ回110kV鼎塑Ⅱ回#2#2#1#1#4#4#4#4220kV鼎美变110kV鼎板Ⅰ回(左线)110kV鼎板Ⅰ回110kV鼎芸Ⅱ回110kV鼎芸Ⅰ回110kV鼎板Ⅱ回(右线)110kV板带变103间隔104间隔#1#1#8#8#9#9#10#17#17甲#17甲#17#10#9#9#8#8#1#1110kV鼎板Ⅱ回197间隔198间隔111间隔199间隔110kV鼎康Ⅰ回110kV鼎板Ⅰ回110kV鼎康Ⅱ回110kV鼎板Ⅱ回110kV鼎板Ⅱ回110kV鼎板Ⅰ回构架110kV长塑变103间隔104间隔110kV鼎塑Ⅱ回110kV鼎塑Ⅰ回二、现场人员布置安排如下表:1、现场负责人:唐勇2、现场安全员:何荣3、现场组员:姚发前、张云东、梁泽均、程伍斌、阳万贵、阳万财、杨邦伟、朋小兵、林功池、吴方团、吴能文、王绍斌、邱文、赵孝禄、谭俊洪、黄弟友、龙建平、王远安、苏水义、陈选武、张龙、吴方仲、陈州、何裕皇、李熙辉等;鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-9-三、施工机具配置如下表:序号机具名称规格单位数量备注1机动绞磨3~5吨台42对讲机健伍kT-308台203经纬仪J2台14导线滑车5吨个305地线滑车3吨个106双钩3~5吨个57地线放线滑车2吨个68拉链葫芦3~6吨台149验电器110kV只210接地线110kV组611绝缘手套10kV套212工具车1.75吨辆213铁5~10吨个514短钢丝绳5~25m根1015钢丝绳1000m条216钢丝绳500m条217钢丝绳50m条2418吊车50T台1四、施工内容:鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-10-4.1停电施工计划三、施工工艺流程:(一)、工作准备1)、所有杆塔在施工前前运至塔位边,横担在地面组装完成,导地线、光缆展放到相应塔位,以保证后续施工的顺利进行。2)、施工前紧线档的两端耐张塔打好临时拉线,对导线架设时有跨越的路序号施工时间施工内容施工人数停电线路停电天数备注104月15日1、110kV鼎芸Ⅰ回#14塔至110kV鼎康Ⅰ回#9塔导地线架设技工:6人普工:8人110kV鼎康Ⅰ回110kV鼎板Ⅰ回110kV鼎塑Ⅰ回12、110kV鼎康Ⅰ回#1塔至110kV鼎康Ⅰ回#9塔地线更换为OPGW光缆技工:13人普工:15人3、拆除110kV鼎康Ⅰ回#9塔与110kV鼎板Ⅰ回#9塔下相导线连接的引线技工:2人普工:2人204月16日1、220kV鼎美变110kV鼎康Ⅰ回构架至鼎康Ⅰ回111间隔引线架设技工:6人普工:8人110kV鼎康Ⅰ回110kV鼎板Ⅰ回110kV鼎塑Ⅰ回12、110kV鼎康Ⅰ回#1塔至110kV鼎康Ⅰ回#9塔地线更换为OPGW光缆技工:13人普工:15人3404月17日1、110kV鼎芸Ⅱ回#14塔至110kV鼎康Ⅱ回#9塔导地线架设技工:6人普工:8人110kV鼎康Ⅱ回110kV鼎板Ⅱ回110kV鼎塑Ⅱ回12、110kV鼎康Ⅱ回#1塔至110kV鼎康Ⅱ回#9塔地线更换为OPGW光缆技工:13人普工:15人3、拆除110kV鼎康Ⅱ回#9塔与110kV鼎板Ⅱ回#9塔下相导线连接的引线技工:2人普工:2人504月18日1、220kV鼎美变110kV鼎康Ⅱ回构架至鼎康Ⅱ回198间隔引线架设。技工:6人普工:8人110kV鼎康Ⅱ回110kV鼎板Ⅱ回110kV鼎塑Ⅱ回12、110kV鼎康Ⅱ回#1塔至110kV鼎康Ⅱ回#9塔地线更换为OPGW光缆技工:13人普工:15人鼎美-芸伟110kVⅠⅡ回线路工程立塔架线施工方案-11-段提前搭好跨越架,跨越架跨公路高度不小于5.5m。(二)、50t吊车组立钢管杆方案一、选用起重机吊钢管杆方法必须具备的条件:(1)运输道路条件。要考虑起重机能否进入)钢管杆附近实现吊装作业。各种起重机的质量都不相同,特别是对于较大型的起重型的起重机必须事先对道路、桥梁及涵洞的承受能力进行

1 / 38
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功