WINCC连接SiemensPLC的常用方式一.WINCC使用CP5611通讯卡通过MPI连接PLC................................................................2前提条件...................................................................................................................................21.STEP7硬件组态..............................................................................................................22.安装CP5611通讯板卡......................................................................................................33.添加驱动程序和系统参数设置.........................................................................................34.设置SetPG/PCInterface...................................................................................................35.添加通道与连接设置.........................................................................................................56.连接测试与通讯诊断.........................................................................................................6二.WINCC使用CP5611通讯卡通过PROFIBUS连接PLC....................................................8前提条件...................................................................................................................................8I.STEP7硬件组态...............................................................................................................82.安装CP5611通讯板卡....................................................................................................103.添加驱动程序和设置系统参数.......................................................................................104.设置SetPG/PCInterface.................................................................................................115.添加通道与连接设置.......................................................................................................146.连接测试与通讯诊断.......................................................................................................15三.WINCC使用普通网卡通过TCP/IP连接PLC....................................................................16前提条件.................................................................................................................................161.STEP7硬件组态..............................................................................................................162.设置IP地址与通讯检测.................................................................................................183.添加驱动程序和设置系统参数.......................................................................................194.设置SetPG/PCInterface.................................................................................................205.添加通道与连接设置.......................................................................................................226.连接测试与通讯诊断.......................................................................................................24四.WINCC使用普通网卡通过IndustrialEthernet连接PLC..................................................25前提条件.................................................................................................................................251.STEP7硬件组态..............................................................................................................262.添加驱动程序和设置系统参数.......................................................................................273.设置SetPG/PCInterface.................................................................................................284.添加通道与连接设置.......................................................................................................295.连接测试与通讯诊断.......................................................................................................31说明:1.文档并未列出所有的WINCC连接Siemens品牌PLC的所有方法,只是列举了一些常用的方法。2.在各种连接方式中的参数设置可能会略有不同,在此列出的步骤和参数只是一套可以连通的设置方法。一.WINCC使用CP5611通讯卡通过MPI连接PLC前提条件I)通过CP5611实现PLC系统与WINCC6.0通讯的前提条件是在安装有WINCC的计算机上安装CP5611通讯板卡。II)使用STEP7编程软件能够通过MPI正常连接PLC。1.STEP7硬件组态STEP7设置MPI通讯,具体步骤不在此详述,可参考如下图1.1示:图1.1注意:1.新建一个MPI网络用来通讯,设置MPI网络的地址和波特率,且记住,在随后的设置中需要匹配。2.安装CP5611通讯板卡安装CP5611,并安装驱动程序,具体CP5611的安装过程和注意事项可参考如下链接:.添加驱动程序和系统参数设置打开WINCC工程在TagManagement--SIMATICS7PROTOCOLSUITE-MPI右键单击MPI,在弹出菜单中点击SystemParameter,弹出SystemParameter-MPI对话框,选择Unit标签,查看Logicdevicename(逻辑设备名称)。默认安装后,逻辑设备名为MPI如图1.3所示:图1.2图1.34.设置SetPG/PCInterface进入操作系统下的控制面板,双击SetPG/PCInterface图标。在AccessPointoftheApplication:的下拉列表中选择MPI(WINCC),如图1.4所示,而后在InterfaceParameterAssignmentUsed:的列表中,点击CP5611(MPI),而后在AccessPointoftheApplication:的下拉列表中显示:MPI(WINCC)CP5611(MPI),如图1.5所示:图1.4图1.5设置CP5611的通讯参数,点击Proerties….按钮,弹出Properties-CP5611(MPI)属性对话框,设置参数,如图1.6所示:重要的参数如下所示:Address:CP5611的地址(MPI地址必须唯一,建议设置为0)TransmissionRate:MPI网络的传输速率(默认为187.5Kbps)您可以修改,但必须和实际连接PLC的MPI端口的传输速率相同)HighestStationAddress:MPI网络的最高站地址(必须和PLC的MPI网络参数设置相同)图1.6诊断MPI网络,点击Diagnostic…按钮,进入诊断对话框。如下图所示:Test按钮点击后,显示OK表示CP5611工作正常。点击“Read”按钮后,将显示所有接入MPI网络中的设备的站地址,如果只能读到自己的站地址,此时,请查看MPI网络和硬件连接设置,只有成功读取到CPU的站点地址,才能进行以下的步骤,否则,不可能建立通讯。5.添加通道与连接设置添加驱动连接,设置参数。打开WINCC工程在TagManagement--SIMATICS7PROTOCOLSUITE-MPI,右键单击MPI,在下拉菜单中,点击NewDriverConnection,如图1.7所示,