11-2、三进三出系列(50节600VDC)1-2-1、(160-600KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A160KVA600VDC272242249250/3P250/3P250/3P200KVA600VDC340303311400/3P320/3P320/3P250KVA600VDC425379389500/3P400/3P400/3P300KVA600VDC510454466630/3P500/3P500/3P400KVA600VDC680606622800/3P630/3P630/3P500KVA600VDC8507587771000/3P800/3P800/3P600KVA600VDC10209099151250/3P1000/3P1000/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于600VDC;1-2-2、(160-600KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm2160KVA5050705025200KVA7070957035250KVA70701207035300KVA9595150(70*2)9550400KVA120120240(120*2)12070500KVA150150300(150*2)15070600KVA185185350(185*2)18595注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流);300KVA及以上功率UPS,电池线需采用2-3根并联。1-3、三进三出高频系列(40节480VDC)1-3-1、(30-120KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A30KVA480VDC48456063/3P63/3P80/3P40KVA480VDC646180100/3P100/3P100/3P50KVA480VDC8076100100/3P100/3P125/3P60KVA480VDC9691120125/3P125/3P160/3P280KVA480VDC128121160160/3P160/3P200/3P90KVA480VDC144136180160/3P160/3P200/3P100KVA480VDC160152200250/3P250/3P250/3P120KVA480VDC191182240250/3P250/3P320/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于480VDC;1-3-2、(30-120KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm230KVA161625161040KVA161635161050KVA252535251660KVA252550251680KVA353550351690KVA3535703525100KVA5050705025120KVA7070957035注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流)。1-4、三进三出高频系列(32节±192VDC)1-4-1、(10-60KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A10KVA384VDC16152532/3P32/3P32/3P20KVA384VDC32305063/3P63/3P63/3P30KVA384VDC484575100/3P100/3P100/3P40KVA384VDC6461100100/3P100/3P125/3P50KVA384VDC8076125125/3P125/3P160/3P60KVA384VDC9691150125/3P125/3P200/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于384VDC。31-4-2、(10-60KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm210KVA66106620KVA10101610630KVA161625161040KVA161635161050KVA252535251660KVA2525502516注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流)。1-5、单进单出系列1-5-1、(6-20KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A6KVA240VDC30272532/2P32/2P32/2P10KVA240VDC48453863/2P63/2P63/2P10KVA3/1240VDC17454363/2P63/2P63/2P15KVA3/1240VDC286865100/3P100/3P100/3P20KVA3/1240VDC359185125/3P125/3P125/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于240VDC。1-5-2、(6-20KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm2备注6KVA1010610610KVA161610161010KVA3/11616161610415KVA3/1161616161020KVA3/12525252510注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流);2-2、三进三出工频系列(29节348VDC)2-2-1、10-400KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A10KVA348VDC28152832/3P32/3P32/3P20KVA348VDC37305563/3P63/3P63/3P30KVA348VDC56458380/3P80/3P100/3P40KVA348VDC7561110100/3P100/3P125/3P50KVA348VDC9476138100/3P100/3P160/3P60KVA348VDC11291166125/3P125/3P200/3P80KVA348VDC150121221160/3P160/3P250/3P100KVA348VDC187152276250/3P250/3P320/3P120KVA348VDC225182331250/3P250/3P320/3P160KVA348VDC300242442320/3P250/3P500/3P200KVA348VDC374303552400/3P400/3P630/3P250KVA348VDC468379690500/3P500/3P800/3P300KVA348VDC561455828630/3P500/3P800/3P400KVA348VDC7486061105800/3P630/3P1250/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于348VDC。2-2-2、(10-400KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm210KVA101010101020KVA161616161030KVA161625161040KVA252535251650KVA252535251660KVA353550351680KVA3535503516100KVA50507050255120KVA7070957035160KVA9595959550200KVA9595150(70*2)9550250KVA120120185(95*2)12070300KVA185185240(120*2)18595400KVA240240480(240*2)240120注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流)。2-3、三进三出工频系列(30节360VDC)2-3-1、(10-60KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A10KVA360VDC28152732/3P32/3P32/3P20KVA360VDC37305463/3P63/3P63/3P30KVA360VDC56458080/3P80/3P100/3P40KVA360VDC7561107100/3P100/3P125/3P50KVA360VDC9476134100/3P100/3P160/3P60KVA360VDC11291160125/3P125/3P200/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于360VDC。2-3-2、(10-60KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm210KVA10101010620KVA161616161030KVA161625161040KVA252535251650KVA252535251660KVA3535503516注:实际电缆线径不得小于表中线径;电缆的截面积是按铜芯电缆计算的(如果用铝芯电缆则需增加30%)同时考虑了温度的上升以及最多15米(交流回路)或10米(直流回路)的线路压降。如果线路更长,则要选用截面积更大的电缆(具体可向技术支持部咨询),以保证线路的压降低于3%(交流)或1%(直流);62-4、单进单出工频系列2-4-1、(4-40KVA)空开配置功率电池电压输入电流A输出电流A电池最大电流A输入空开A输出空开A电池空开A4KVA192VDC20182132/2P32/2P32/2P6KVA192VDC30273232/2P32/2P40/2P8KVA192VDC40364263/2P63/2P63/2P10KVA192VDC50455363/2P63/2P63/2P10KVA3/1192VDC17455363/3P63/2P63/2P15KVA3/1192VDC256878100/3P100/3P100/3P20KVA3/1192VDC3491104100/3P100/3P125/3P25KVA3/1192VDC42114128125/3P125/3P160/3P30KVA3/1192VDC51136155160/3P160/3P160/3P40KVA3/1192VDC67182205200/3P200/3P200/3P注:实际开关容量不得小于表中开关容量;电池开关额定工作直流电压,不得低于192VDC。2-4-2、(4-40KVA)电缆配置功率输入电缆mm2输出电缆mm2电池电缆mm2零线mm2地线mm2备注4KVA666666KVA6610668KVA1010101061