西门子 FM 350-1_FM 450-1 功能模块使用手册

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

FM350-1/450-1常见问题分析SLCA&DCSBeijingPage1of7FM350-1常见问题分析目录1高速计数器FM350-1是连结增量型编码器的功能模板。如何做到断电保持上次的计数值·························································································································22升级FM350-1(6ES7350-1AH03-0AE0)的固件版本,从V1.0.0到V1.0.2··········33已经通过CD正确安装配置FM350-1模板的软件,但是在“STEP7V5.1+SP6”的硬件组态中,无法发现硬件FM350-1(6ES7350-1AH03-0AE0)··················34FM350-1(6ES7350-1AH03-0AE0)电子手册·······················································35FM350-1(6ES7350-1AH03-0AE0)的产品信息···················································36下载配置FM350-1,FM450-1的软件包V5.1(03.2003)·······································37当使用IM365扩展接口模板做系统配置时,是否可以使用FM350-1模板···········38数据块部分信息介绍(DATABLOCK)······························································39如何快速预装载计数值·························································································510是否在FM450-1组态包里,用于显示硬件门控制器的图像是颠倒的················611FM450-1在仅仅使用通道0时,模板总报告通道1的信号有错误,外部错误··612FM450-1的电子手册·························································································613FM450-1的快速入门手册“GETTINGSTARTEDMANUAL”··························7FM350-1/450-1常见问题分析SLCA&DCSBeijingPage2of71高速计数器FM350-1是连结增量型编码器的功能模板。如何做到断电保持上次的计数值高速计数模板的计数当前值,都是存储在CPU的数据块DB中,不会丢失。可以如下编程处理:i.在每次CPU上电时候,OB100中进行初始化程序处理——传递CPU数据块DB中的当前计数值DBD34,放置到装载数值DBD14中。调用功能块“CNT_CTL1Function”,置位操作“L_PREPAR”;ii.在OB1中调用功能块“CNT_CTL1Function”,使用脉冲上升沿信号触发操作“L_DIRREC”;iii.即可以做到断电保持上次的计数值,开始正常的高速计数操作。FM350-1/450-1常见问题分析SLCA&DCSBeijingPage3of72升级FM350-1(6ES7350-1AH03-0AE0)的固件版本,从V1.0.0到V1.0.2请点击:在线阅读“FirmwareUpdatesforFM350-1(6ES7350-1AH03-0AE0)”。3已经通过CD正确安装配置FM350-1模板的软件,但是在“STEP7V5.1+SP6”的硬件组态中,无法发现硬件FM350-1(6ES7350-1AH03-0AE0)请点击:在线阅读“FM350-1isnotparametrizablewithSTEP7smallerthanV5.2”。4FM350-1(6ES7350-1AH03-0AE0)电子手册请点击:在线“下载”或者“阅读”。5FM350-1(6ES7350-1AH03-0AE0)的产品信息请点击:在线阅读。6下载配置FM350-1,FM450-1的软件包V5.1(03.2003)请点击:在线下载。7当使用IM365扩展接口模板做系统配置时,是否可以使用FM350-1模板请点击:和在线阅读FAQ。8数据块部分信息介绍(DataBlock)FM350-1/450-1常见问题分析SLCA&DCSBeijingPage4of7用户所需要的模板状态信息,CPU通过功能块FCCNT_CTL1对FM350-1模板的控制,均需要通过库中的UDT2生成的DataBlock来完成。每一个FM350-1都需要一个相对应的DataBlock,里面包含FM350-1的逻辑地址、功能、状态信息,等等。在模板参数配置之前,必须给该DataBlock中的重要数据分配数据,如:模板地址(DBW6),通道地址(DBD8),等等。地址变量名称数据类型初始值功能描述模板参数,地址信息0.0AR1_BUFFERDWORDDW#16#0AR1缓冲区4.0FPBYTEB#16#0标志位6.0MOD_ADRWORDW#16#0模板地址8.0CH_ADRDWORDDW#16#0通道地址12.0U_D_LGTHBYTEB#16#0用户数据长度用于“写操作”的数据区14.0LOAD_VALDINTL#0新的计数装载值18.0CMP_V1DINTL#0新的比较值122.0CMP_V2DINTL#0新的比较值2用于“控制操作”的数据区27.0ENSET_UPBOOLFALSE使能操作:计数方向为“上”27.1ENSET_DNBOOLFALSE使能操作:计数方向为“下”28.0CTRL_DO0BOOLFALSE使能操作“DO0输出”有效28.1CTRL_DO1BOOLFALSE使能操作“DO1输出”有效用于“读操作”的数据区30.0LATCH_LOADDINTL#0当前的装载值,测量值34.0ACT_CNTVDINTL#0当前的高速计数值用于显示“出错信息”的数据区38.0DA_ERR_WWORDW#16#0数据错误信息40.0OT_ERR_BBYTEB#16#0操作错误信息用于显示模板“反馈信息”的数据区41.4DATA_ERRBOOLFALSE数据出错41.7PARABOOLFALSE模板已经被正确参数化配置43.0STS_RUNBOOLFALSE高速计数器正在工作否?FM350-1/450-1常见问题分析SLCA&DCSBeijingPage5of743.1STS_DIRBOOLFALSE高速计数的计数方向?43.2STS_ZEROBOOLFALSE经过“零”脉冲信号43.3STS_OFLWBOOLFALSE计数值上溢出43.4STS_UFLWBOOLFALSE计数值下溢出43.5STS_SYNCBOOLFALSE计数器同步43.6STS_GATEBOOLFALSE内部门的状态43.7STS_SW_GBOOLFALSE软件门的状态44.0STS_SETBOOLFALSE数字量输入点的状态44.1STS_LATCHBOOLFALSE(仅仅用于时钟同步模式),新的44.2STS_STABOOLFALSE用于“开始”功能数字量输入点状态44.3STS_STPBOOLFALSE用于“停止”功能数字量输入点状态44.4STS_CMP1BOOLFALSE“比较值1”数字量输出点状态44.5STS_CMP2BOOLFALSE“比较值2”数字量输出点状态44.6STS_COMP1BOOLFALSE比较器1的状态44.7STS_COMP2BOOLFALSE比较器2的状态用于功能块“FCDIAG_INF”的模板诊断信息54.0MDL_DEFECTBOOLFALSE模板出错54.1INT_FAULTBOOLFALSE内部错误54.2EXT_FAULTBOOLFALSE外部错误54.3PNT_INFOBOOLFALSE通道错误54.4EXT_VOLTAGEBOOLFALSE辅助电压错误54.5FLD_CONNCTRBOOLFALSE前联结器错误54.6NO_CONFIGBOOLFALSE没有参数化54.7CONFIG_ERRBOOLFALSE参数配置错误其余,参见手册“第10章节”(DBAssignments)。9如何快速预装载计数值为了尽可能快速地完成预装载计数值到高速计数器的寄存器中,可以分两部分来做:i.传递新的装载值到数据块DB中的装载数值DBD14中;ii.调用功能块“CNT_CTL1Function”,置位操作“L_PREPAR”;iii.通过模板的数字量输入点“DISet”,完成装载计数值的快速操作。FM350-1/450-1常见问题分析SLCA&DCSBeijingPage6of710是否在FM450-1组态包里,用于显示硬件门控制器的图像是颠倒的在FM450-1组态包里的“输入”窗口中,用于显示硬件门控制器的图像是颠到的。“边缘-控制的硬件门(DI启动,DI停止)”所用的图像被分配给了参数选项“电平-控制的硬件门(DI启动)”。而“电平-控制的硬件选通(DI启动)”用的图像被分配给了参数选项“边缘-控制的硬件选通(DI启动,DI停止)”。这种显示纯属组态包里的图形错误,并不影响模块功能或模块的参数化。该输入的选定的参数化在FM450-1上实施。图1:在FM450-1用的组态包里图像的颠倒。请点击:在线阅读FAQ。11FM450-1在仅仅使用通道0时,模板总报告通道1的信号有错误,外部错误请点击:在线阅读FAQ。12FM450-1的电子手册FM350-1/450-1常见问题分析SLCA&DCSBeijingPage7of7请点击:下载或者在线阅读。13FM450-1的快速入门手册“GettingStartedManual”请点击:下载或者在线阅读。

1 / 7
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功