目录第一章工程概况.................................................................................-1-1.1管道工程........................................................................................-1-1.2电气工程.......................................................................................-2-1.3通风工程.......................................................................................-3-第二章编制依据................................................................................-4-第三章施工布署................................................................................-4-3.1施工管理机构................................................................................-4-3.2工程施工目标................................................................................-5-3.3施工工期组织及施工进度计划....................................................-5-一、施工工期网络进度计划.........................................................-5-二、施工工期组织原则...................................................................-5-三、工期保证措施.........................................................................-6-3.4劳动力投入计划............................................................................-6-3.5物资供应计划................................................................................-6-3.6施工机具设备投入计划................................................................-7-3.7临时设施布置计划........................................................................-8-3.8施工准备........................................................................................-9-第四章主要施工方案...........................................................................104.1管道工程...........................................................................................104.2电气工程...........................................................................................244.3通风管道工程...................................................................................41第五章施工配合措施.........................................................................455.1安装与建设单位的配合...................................................................455.2安装与监理公司的配合...................................................................455.3安装配合土建施工措施...................................................................455.4与其它工种的配合...........................................................................46第六章施工质量保证措施...................................................................466.1质量管理...........................................................................................46一、质量管理组织措施......................................................................46二、质量保证措施..............................................................................47三质量控制措施:..........................................................................476.2工程成品、半成品管理和内业技术资料管理...............................48一、工程成品、半成品管理..........................................................48二、施工内业管理:..........................................................................496.3工程所需的施工标准、规范...........................................................506.4工程回访及保修办法.......................................................................51第七章质量通病防治措施...................................................................52第八章安全文明施工保证措施...........................................................538.1安全工作重点及保证措施...............................................................538.2文明生产管理措施...........................................................................548.3施工现场消防及治安保卫工作.......................................................54第九章成品保护措施.............................................................................55浙江中富建筑集团股份有限公司-1-第一章工程概况1.1管道工程1、生活给水系统本工程各楼共用一套生活泵和地下水池,设于地下汽车库的集中泵房内。采用生活水池——生活水泵——各单元屋顶水箱——减压阀供水方式。由屋顶水箱水位自动控制泵的运行。地下生活水池为混凝土水池,独立结构,内衬不锈钢。生活水泵基础做减振器和隔振台座,并在进出水管上安装弹性可曲挠橡胶接头,出水管上安装消音止回阀,防止噪音及停泵时水锤的产生。本工程最大日用水量:465吨/日;最大时用水量:48.5吨/时。2、污废水系统室内住宅采用污废水分流制。住宅内的各厨房及卫生间的污废水,分别汇集于管道井的排水立管,各排水立管汇集后,统一排入室外污水管网。底层污、废水单独排至室外。本工程最大日排水量:442吨/日。3、雨水、冷凝水系统屋面阳台雨水及空调冷凝水排入室外明沟,由雨水收水口接入室外雨水窨井。屋面雨水排入室外明沟或直接接入室外雨水窨井。4、管材和连接方式(1)水表前生活给水管采用钢塑复合管,螺纹连接。给水表后冷、热水支管均采用聚丙烯PPR塑料管,热熔连接;与金属管件或卫生洁具五金配件联结时则采用带金属嵌件的管件,丝扣连接,用聚四氟乙烯带作为密封填充物;水箱内浸水部分管道采用内外涂塑焊接钢管及管件。管道压力等级:表前PN1.6;表后冷水管PN1.0;热水管PN2.0。PPR管与热水器连接时设不小于400MM的金属管过滤。(2)净废水立管、污水立管管件均采用硬聚氯乙烯内螺旋管,不设专用通气立管。横管接入立管的三通和四通管件,采用具有螺母挤压密封圈接头的旋转进水型管件。浙江中富建筑集团股份有限公司-2-(3)雨水管均采用硬聚氯乙烯排水管,不加粘接剂承插连接。5、管道敷设(1)给水管给水立管明敷,其余冷、热水管道原则上暗敷,给水管道穿梁和墙时设钢套管,管径放大二档;所有给水管道设支、吊架固定牢靠。每户设DN20干式水表一只,安装在给水管道井内,水表前采用铜球阀,其余为铜芯闸阀。(2)排水管卫生间内排水立管设于管道井内,有清扫口的地方管井上设检修门;厨房内废水立管唷眼建筑包封,所有排水横管均明敷;所有排水管道设支、吊架固定牢靠。楼层排水横管以标准坡度i=2.6%坡向立管;排水横管靠顶板安装。污、废水立管在底层、顶层和中间每六层离地一米处设检查口;立管底部采用二个45度弯头,存水弯均采用门弯。排水横管起始弯头带检查门,所需弯头尽量采用45度弯头,所用三通采用二个45度三通或90度三通,排水管零件采用顺水式。排水立管每层设一伸缩节,设在楼板下排水支管汇合三通之下。De≥110的排水管在穿越楼板和管道井壁处均设置阻火圈,地坪上沿排水立管外壁四周再粉高20-25mm作阻水圈。伸顶透气管上的透气帽中心距屋顶完成面均为0.5米,在经常有人停留的平屋面上透气帽中心距屋顶完成面均为2.2米。排水出户管在土建结顶后敷设,避开初期沉降;出户管穿地下室外墙时预埋防水套管,室外埋地管道做好垫层和混凝土基础。1.2电气工程1、供电电源本工程的电力负荷采用二级负荷。供电电源为双电源供电,供电电压为380/220V,由供电部门采用电缆埋地从小区变电所引出。2、配电方式浙江中富建筑集团股份有限公司-3-采用放射式配电系统,照明干线和动力干线分别设置。3、敷线方式本工程的车库照明采用BV—500线穿线槽明敷,应急疏散照明采用ZR—BV—500型导线穿钢管暗敷,从