国家电网公司湖北电网集中规模招标招标文件AC20kV真空开关高压开关柜专用技术规范国网武汉供电公司目次1标准技术参数表·············································································································2项目需求部分················································································································2.1货物需求及供货范围一览表······························································································2.2必需的备品备件、专用工具和仪器仪表供货表·········································································2.3图纸资料提交单位········································································································2.4工程概况··················································································································2.5使用条件··················································································································2.6项目单位要求值··········································································································2.7项目单位技术偏差表·····································································································3投标人响应部分·············································································································3.1技术偏差表(投标人填写)······························································································3.2投标产品的销售及运行业绩表···························································································3.3投标人需提供的设备图纸及资料························································································3.4主要组部件材料··········································································································3.5推荐的备品备件、专用工具和仪器仪表供货表·········································································1标准技术参数表投标人应认真逐项填写技术参数响应表(见表1)中“投标人保证值”,不能空格,也不能以“响应”两字代替,不允许改动招标人要求值。如有偏差,请填写项目单位技术偏差表(见表7)。“投标人保证值”应与型式试验报告相符。表1技术参数响应表(投标人填写)序号名称单位标准参数值投标人保证值一开关柜共用参数1结构型式中置式(投标人填写)2额定电压kV24(投标人填写)3额定频率Hz50(投标人填写)4额定电流A1250(投标人填写)5温升试验1.1Ir(投标人填写)6额定工频1min耐受电压断口kV79(投标人填写)对地65(投标人填写)7额定雷电冲击耐受电压峰值(1.2/50s)断口kV145(投标人填写)对地125(投标人填写)8额定短路开断电流kA25(投标人填写)9额定短路关合电流kA63(投标人填写)10额定短时耐受电流及持续时间kA/s25/4(投标人填写)11额定峰值耐受电流kA63(投标人填写)12辅助和控制回路短时工频耐受电压kV2(投标人填写)13局部放电试验电压kV1.1×24/3(投标人填写)单个绝缘件pC≤3(投标人填写)电压互感器、电流互感器≤10(投标人填写)14供电电源控制回路VAC220(投标人填写)辅助回路VAC220(投标人填写)15使用寿命年≥30(投标人填写)16设备尺寸单台开关柜整体尺寸(长×宽×高)mm宽度≥1000(投标人填写)设备的最大运输尺寸(长×宽×高)(投标人填写)(投标人填写)17防护等级柜体外壳—IP41(投标人填写)隔室间IP2X(投标人填写)18爬电距离瓷质材料(对地)mm≥432(投标人填写)有机材料(对地)≥480(投标人填写)19相间及相对地净距(空气绝缘)mm≥180(投标人填写)20丧失运行连续性类别—LSC2B(投标人填写)21绝缘套或硫化涂覆—厚度满足相应等级绝缘水平要求,热缩套要求采用优质产品22SMC隔板到导体绝缘套或硫化涂覆的最小净距mm≥4523SMC隔板厚度mm≥524外壳材料敷铝锌钢板25柜壁厚度mm≥226断路器布置型式—小车27小车推进机构—手动28冷却方式—自冷29加热器功率—(投标人填写)30内部电弧允许持续时间s0.5二断路器参数1型式—采用一体化弹簧操作机构真空断路器,固封极柱式(环氧树脂)。(投标人填写)2额定电压kV243额定频率Hz504额定电流A1250(投标人填写)5主回路电阻(投标人填写)(投标人填写)6温升试验—1.1Ir(投标人填写)7额定工频1min耐受电压断口kV79(投标人填写)对地65(投标人填写)额定雷电冲击耐受电压峰值(1.2/50s)断口kV145(投标人填写)对地125(投标人填写)8额定短路开断电流交流分量有效值kA25(投标人填写)时间常数ms45(投标人填写)开断次数次≥30(投标人填写)首相开断系数—1.5(投标人填写)9额定短路关合电流kA63(投标人填写)10额定短时耐受电流/持续时间kA/s25/4(投标人填写)11额定峰值耐受电流kA63(投标人填写)12开断时间ms≤60(投标人填写)13合闸弹跳时间ms≤2(投标人填写)14分闸时间ms≤45(投标人填写)15合闸时间ms≤70(投标人填写)16重合闸无电流间隙时间ms300(投标人填写)17分/合闸平均速度分闸速度m/s(投标人填写)(投标人填写)合闸速度(投标人填写)(投标人填写)18分闸不同期性ms≤2(投标人填写)19合闸不同期性ms≤2(投标人填写)20机械稳定性次≥30000(投标人填写)21额定操作顺序—馈线:O—0.3s—CO—180s—CO(投标人填写)22辅助和控制回路短时工频耐受电压kV223异相接地故障开断试验—3/2倍额定短路开断电流24容性电流开合试验(试验室)试验电流A电缆:25电容器组≥400(投标人填写)试验电压kV1.4×24/3(投标人填写)C1级:CC1:24×OCC2:24×COBC1:24×OBC2:24×CO—C2级(投标人填写)C2级:CC1:24×O;CC2:24×CO;BC1:24×O;BC2:80×CO25操动机构型式或型号—一体化弹操(投标人填写)操作方式—三相机械联动(投标人填写)电动机电压VAC/DC220DC110(投标人填写)合闸操作电源额定操作电压VAC/DC220DC110(投标人填写)操作电压允许范围85%~110%,30%不得动作(投标人填写)每相线圈数量只1(投标人填写)合闸线圈涌入功率W180W/200W(220V/110V)(投标人填写)合闸线圈消耗功率W180W/200W(220V/110V)(投标人填写)分闸操作电源额定操作电压VDC220、DC110(AC/DC220DC110)(投标人填写)操作电压允许范围65%~110%,30%不得动作(投标人填写)每相线圈数量只1(投标人填写)合闸线圈涌入功率W180W/200W(220V/110V)(投标人填写)合闸线圈消耗功率W180W/200W(220V/110V)(投标人填写)26备用辅助触点数量对8动合,8动断(投标人填写)额定电流AAC10A/DC6A(投标人填写)检修周期年≥10(投标人填写)弹簧机构储能时间s≤15(投标人填写)27真空灭弧室真空度Pa≤1.33×103三接地开关参数1额定短时耐受电流及持续时间kA/s25/4(投标人填写)2额定峰值耐受电流kA63(投标人填写)3额定关合电流kA63(投标人填写)4额定关合次数—2(投标人填写)5机械稳定性次≥3000(投标人填写)6操动机构型式或型号—手动(投标人填写)电动机电压V(投标人填写)控制电压V(投标人填写)允许电压变化范围—(投标人填写)操作方式—三相机械联动备用辅助触点数量对4动合,4动断(投标人填写)额定电流AAC10A/DC6A(投标人填写)四电流互感器参数1型式或型号环氧树脂浇注式(投标人填写)2绕组1额定电流比—(按设计图)(投标人填写)额定负荷—(按设计图)(投标人填写)准确级—10P25(投标人填写)绕组2额定电流比—(按设计图)(投标人填写)额定负荷—(按设计图)(投标人填写)准确级—10P25(投标人填写)绕组3额定电流比—(按设计图)(投标人填写)额定负荷—(按设计图)(投标人填写)准确级—0.5(投标人填写)绕组4额定电流比—(按设计图)(投标人填写)额定负荷—(按设计图)(投标人填写)准确级—0.2S(投标人填写)五零序电流互感器(若有)1型式—抱箍式速饱和型,符合凝露试验验证产品(投标人填写)2额定电流比—150/5A(投标人填写)3额定负荷VA3(投标人填写)4六电压互感器及熔断器参数1型式或型号—环氧树脂浇注式,单相,全绝缘(投标人填写)2额定电压比—24/√3:0.1/√3:0.1/√3:0.1/3(投标人填写)3准确级—0.2/0.5/3P(投标人填写)4接线级别—Yn/yn/yn/△(投标人填写)5额定容量VA(根据工程需要)(投标人填写)6三相不平衡度V1(投标人填写)7低压绕组1min工频耐压kV2(投标人填写)8额定电压因数—1.2倍连续,1.9倍8h(投标人填写)9熔断器型式—高压限流型熔断器(投标人填写)10熔断器的额定电流A1A(投标人填写)11熔断器的额定短路开断电流kA31.5kA(投标人填写)12消谐器—(根据工程需要)七避雷器参数1型式—复合绝缘金属氧化物避雷器(投标人填写)2额定电压kV33.8(投标人填写)3持续运行电压kV27(投标人填写)4标称放电电流kA5(投标人填写)5陡波冲击电流下残压峰值(5kA,1/3s)kV≤86.7(投标人填写)6雷电冲击电流下残压峰值(5kA,8/20s)kV≤78.6(投标人填写)7操作冲击电流下残压峰值(250A,30/60s)kV≤66.4(投标人填写)8直流1mA参考电压kV≥73(投标人填写)八母线