**********工程处施工技术方案第1页共29页总厂老区消防水管线改造新旧管线碰头施工方案*********安装工程处化工石油项目部**********工程处施工技术方案第2页共29页1工程概况及工程量.......................................................................................................................31.1工程概况............................................................................................................................31.2工程量及工期....................................................................................................................32编制依据.....................................................................................................................................153施工程序、方法.........................................................................................................................153.1施工前准备......................................................................................................................153.2施工人员..........................................................................................................................153.3施工机具..........................................................................................................................163.4材料..................................................................................................................................163.5安全器具..........................................................................................................................173.6工序交接..........................................................................................................................173.7降水方案..........................................................................................................................174施工程序、方法和内容.............................................................................................................194.1施工方案..........................................................................................................................194.2施工工艺流程..................................................................................................................204.3施工方法及要求..............................................................................................................205质量标准及要求.........................................................................................................................235.1焊接钢管管道:..............................................................................................................235.2质量管理网络..................................................................................................................246施工的安全要求和环境条件.....................................................................................................246.1施工的安全要求..............................................................................................................246.2环境条件..........................................................................................................................256.3消防管理..........................................................................................................................256.4施工安全因素危害辨识和控制......................................................................................256.5应急预案..........................................................................................................................27**********工程处施工技术方案第3页共29页1工程概况及工程量1.1工程概况本工程为总厂老区消防水管线改造工程,由于总厂老区消防水管线年久失修,部分老管线漏水,现一期更换部分已施工完毕。本方案为新老管线碰头及与原装置内消防栓、消防炮的碰头方案,新消防水主管道为DN350、DN400及DN450,新管道埋深在自然地坪以下1.4m,旧管道埋深在自然地坪一下约2.4m左右,由于本工程施工地点地下水位较高,需对每个新老管线碰头位置使用井点以降低地下水位。地上式消火栓,管材采用焊接钢管,管材防腐采用新型的“两布三油”防腐技术,管道通水运行后工作压力为0.8MPa,水压试验压力为1.6MPa。1.2工程量及工期1.21工程量(详细位置见附图)厂区内新老消防管线需碰头的有25处,新接出地上式消防炮2处,新管线相接1处。碰头位置焊接详图新消防管线旧消防管线挖眼三通90°弯头盲板新老管线碰头简易图**********工程处施工技术方案第4页共29页1号位置4号路与动力站北侧材料表名称规格及型号单位数量备注弯头90°个2盲板块2变径个1钢管米约4钢管米1挖眼三通个2此接头位置为新老消防管线接头,新消防管线埋深1.4米处,旧消防管线埋深2.4米处,需要使用井点降水。a确定此处新老消防管线的碰头位置,根据本碰头位置的基坑开挖来确定需用多少降水井点。b采用大型挖掘机进出场配合人工对碰头位置进行挖土,挖至老管线位置,并留出碰头操作面。c管道碰头须将老管道切割,并将管内积水排除干净,保持接口干燥。d将新老管线用弯头及直管相连接。e将废弃的旧消防管道用盲板封口f施工完毕,现场需清理干净,所有垃圾运至指定位置。2号位置4号路北侧柴油加氢精制装置东南角材料表名称规格及型号单位数量备注弯头90°个2新消防管线旧消防管线90°弯头挖眼三通盲板消防炮新管线与消防炮、消防栓碰头简易图**********工程处施工技术方案第5页共29页盲板块2变径个1钢管米约4钢管米1挖眼三通个2此接头位置为新老消防管线接头,新消防管线埋深1.4米处,旧消防管线埋深2.4米处,需要使用井点降水。a确定此处新老消防管线的碰头位置,根据本碰头位置的基坑开挖来确定需用多少降水井点。b采用大型挖掘机进出场配合人工对碰头位置进行挖土,挖至老管线位置,并留出碰头操作面。c管道碰头须将老管道切割,并将管内积水排除干净,保持接口干燥。d将新老管线用弯头及直管相连接。e将废弃的旧消防管道用盲板封口f施工完毕,现场需清理干净,所有垃圾运至指定位置。3号位置4号路北侧柴油加氢精制装置东南角材料表名称规格及型号单位数量备注弯头90°个2盲板块2变径个1钢管米约4钢管米1挖眼三通个2此接头位置为新老消防管线接头,新消防管线埋深1.4米处,旧消防管线埋深2.4米处,需要使用井点降水。a确定此处新老消防管线的碰头位置,根据本碰头位置的基坑开挖来确定需用多少降水井点。b采用大型挖掘机进出场配合人工对碰头位置进行挖土,挖至老管线位置,并留出碰头操作面。c管道碰头须将老管道切割,并将管内积水排除干净,保持接口干燥。d将新老管线用弯头及直管相连接。e将废弃的旧消防管道用盲板封口f施工完毕,现场需清理干净,所有垃圾运至指定位置。4号位置4号路北侧柴油加氢精制装置东南角材料表名称规格及型号单位数量备注弯头90°个2盲板块2变径个1钢管米约4钢管米1**********工程处施工技术方案第6页共29页挖眼三通个2此接头位置为新老消防管线接头,新消防管线埋深1.4米处,旧消防管线埋深2.4米处,需要使用井点降水。a确定此处新老消防管线的碰头位置,根据本碰头位置的基坑开挖来确定需用多少降水井点。b采用大型挖掘机进出场配合人工对碰头位置进行挖土,挖至老管线位置,并留出碰头操作面。c管道碰头须将老管道切割,并将管内积水排除干净,保持接口干燥。d将新老管线用弯头及直管相连接。e将废弃的旧消防管道用盲板封口f施工完毕,现场需清理干净,所有垃圾运至指定位置。5号位置4号路北侧柴油加氢精制装置东南角材料表名称规格及型号单位数量备注弯头90°个2盲板块2变径个1钢管米约4钢管米1挖