ICSDB21辽宁省地方标准DB21/Txxxx—2011额定电压300/500V及以下风力发电机机舱用耐低温薄壁绝缘和护套控制电缆Thinwallinsulatedandsheathedcontrolcableswithlowtemperatureresistanceforratedvoltagesuptoandincluding300/500Vforcabinofwindturbinegenerator(报批稿)(本稿完成日期:2011-06-15)2011-XX-XX发布2011-XX-XX实施辽宁省质量技术监督局发布DB21/Txxxx—2011I目次前言................................................................................II1范围..............................................................................12规范性引用文件....................................................................13术语和定义........................................................................14使用特性..........................................................................25型号和产品表示方法................................................................26规格..............................................................................37技术要求..........................................................................48成品电缆..........................................................................69交货长度..........................................................................810检验规则和试验方法...............................................................811包装标志.........................................................................812运输和储存.......................................................................9DB21/Txxxx—2011II前言本标准的编写符合GB/T1.1-2009.本标准由辽宁省产品质量监督检验院提出。本标准由辽宁省电线电缆标准化技术委员会(LN/TC1102)归口。本标准起草单位:辽宁省产品质量监督检验院。本标准主要起草人:于洪才、郑忠言、刘伟、陈继、孙蕊、宋旭。本标准为首次制定。DB21/Txxxx—20111额定电压300/500V及以下风力发电机机舱用耐低温薄壁绝缘和护套控制电缆1范围本标准规定了额定电压300/500V及以下风力发电机机舱用耐低温薄壁绝缘和护套控制电缆的型号、规格、技术要求、成品电缆、交货长度、检验规则及试验方法、包装标志、运输和储存等内容。本标准适用于寒冷地区风力发电机机舱内传输信号等使用的控制电缆。2规范性引用文件下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误内容)或修订版均不适用于本标准。然而,鼓励根据本标准达成协议的各方面研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。GB/T2900.10-2001电工术语电缆GB/T2951-2008电缆和光缆绝缘和护套材料通用试验方法GB/T3048-2007电线电缆电性能试验方法GB/T3956-2008电缆的导体GB/T6995-2008电线电缆识别标志方法JB/T8137-1999电线电缆交货盘GB/T19666-2005阻燃和耐火电线电缆通则3术语和定义3.1额定电压电缆的额定电压是电缆设计、使用和进行电性能试验用的基准电压。额定电压用U0/U表示。U0表示任一主绝缘导体与“地”(金属屏蔽或周围介质)之间的电压有效值;U为多芯电缆任意两相导体之间的电压有效值。在交流系统中,电缆的额定电压至少应等于使用电缆的系统的标称电压,这个条件对U0和U都适用;在直流系统中,该系统的标称电压应不大于电缆额定电压的1.5倍。系统的工作电压应不大于系统标称电压的1.1倍。3.2例行试验由制造方在成品电缆的所有制造长度上进行的试验。3.3DB21/Txxxx—20112抽样试验按规定的频度在成品电缆试样上或在取自成品电缆的元件上进行的试验,以检验成品电缆产品符合规定要求。3.4型式试验按一般商业原则对本技术规范所包含的一种类型电缆在供货前所进行的试验,以证明电缆具有能满足预期使用条件的良好性能。注1:型式试验的特点是除非电缆材料、设计或制造工艺改变可能改变电缆特性,试验做过以后不需要重做。4使用特性4.1电缆额定电压电缆额定电压U0/U为300/500V。4.2电缆工作温度电缆导体长期允许最高工作温度为70℃。4.3电缆敷设温度电缆敷设温度应不低于-10℃。电缆工作环境最低温度-40℃。4.4电缆最小弯曲半径电缆的最小弯曲半径为电缆直径的6倍。5型号和产品表示方法5.1代号风力发电机用电缆系列代号.........................................................FJ聚氯乙烯绝缘和护套控制电缆........................................................K镀锡铜丝编织......................................................................P薄壁绝缘和护套....................................................................B5.2型号电缆型号见表1表1电缆型号型号额定电压名称FJKP/B300/500V铜芯聚氯乙烯薄壁型绝缘和护套镀锡铜丝屏蔽控制电缆FJK/B300/500V铜芯聚氯乙烯薄壁型绝缘和护套控制电缆5.3产品表示方法产品用型号、规格和标准编号表示,规格包括额定电压、芯数和标称截面等。DB21/Txxxx—201136规格电缆规格及相应参数见表2表2电缆规格及相应参数型号芯数×标称截面/mm2导体内最大单丝直径/mm绝缘厚度标称值/mm护套厚度标称值/mm编织屏蔽单线直径/mm铝塑复合带厚度/mm平均外径/mm20℃时导体最大电阻/(Ω/km)下限上限FJKP/B2×0.50.200.50.90.150.0255.77.840.1FJKP/B4×0.50.200.50.90.150.0256.18.040.1FJKP/B2×0.750.200.50.90.150.0255.87.426.7FJKP/B4×0.750.200.50.90.150.0256.58.526.7FJKP/B7×0.750.200.51.10.150.0258.410.326.7FJKP/B4×2×0.750.200.51.20.150.02510.412.826.7FJKP/B12×0.750.200.51.20.150.02510.513.026.7FJKP/B24×0.750.200.51.50.150.02515.518.026.7FJKP/B2×1.00.200.60.90.150.0256.78.620.0FJKP/B18×1.00.200.61.50.150.02515.118.820.0FJKP/B4×1.50.200.61.10.150.0259.111.013.7FJKP/B5×1.50.200.61.10.150.0259.812.013.7FJKP/B7×1.50.200.61.20.150.02511.013.013.7FJKP/B12×1.50.200.61.50.150.02514.017.113.7FJKP/B4×2.50.200.71.20.150.02510.012.78.21FJKP/B7×2.50.200.71.30.150.02511.914.58.21FJKP/B4×40.300.81.40.150.02513.716.55.09FJKP/B4×100.300.91.60.150.02517.421.81.95FJK/B2×0.750.200.50.9——5.87.526.7FJK/B4×0.750.200.50.9——6.98.626.7FJK/B12×0.750.200.51.2——10.813.626.7FJK/B2×1.00.200.60.9——6.88.620.0FJK/B7×1.00.200.61.0——8.410.820.0FJK/B18×1.00.200.61.5——16.018.520.0FJK/B2×1.50.200.61.0——7.010.213.7FJK/B4×1.50.200.61.0——8.410.513.7FJK/B7×1.50.200.61.1——10.112.613.7FJK/B12×1.50.200.61.5——14.517.013.7FJK/B4×2.50.200.71.2——10.112.98.21FJK/B4×40.300.81.4——13.616.15.09FJK/B4×60.300.81.5——13.917.53.39FJK/B7×60.300.81.5——15.118.03.39DB21/Txxxx—201147技术要求7.1导体7.1.1导体应采用镀锡退火软铜线,单丝直径应符合表2规定。7.1.2导体20℃时的电阻值应符合表2规定。7.1.3导体其余未尽事项应符合GB/T3956要求。7.2绝缘7.2.1材料绝缘应为热塑性柔软型聚氯乙烯,其机械性能应符合表3规定。7.2.2绝缘层绝缘应紧密挤包在导体上,且应容易剥离而不损伤绝缘体和导体。绝缘厚度应符合表2规定。绝缘厚度的平均值应不小于标称值,其最薄处厚度应不小于标称值的90%减去0.1mm。绝缘线芯应按GB/T3048.9-2007经受交流50Hz,试验电压6kV的火花试验检查。表3绝缘和护套机械性能序号试验项目单位技术指标试验方法1抗张强度和断裂伸长率GB/T2951.11-20081.1交货状态原始性能1.1.1抗张强度最小中间值N/mm210.01.1.2断裂伸长率最小中间值%1501.2空气烘箱老化后的性能GB/T2951.12-20081.2.1老化条件:——温度℃80±2——时间h7×241.2.2老化后抗张强度——最小中间值N/mm210.0——最大变化率%±201.2.3老化后断裂伸长率——最小中间值%150——最大变化率%±202失重试验GB/T2951.32-20082.1老化条件:——温度℃80±2——时间h7×242.2失重最大值mg/cm22.0DB21/Txxxx—20115表3(续)绝缘和护套机械性能序号试验项目单位技术指标试验方法3热冲击试验GB/T2951.31-20083.1老化条件:——温度℃150±3——时间h13.2试验结果不开裂4高温压力试验GB/T2951.31-2