机柜微环境

整理文档很辛苦,赏杯茶钱您下走!

免费阅读已结束,点击下载阅读编辑剩下 ...

阅读已结束,您可以下载文档离线阅读编辑

资源描述

©SynclocCorporation.Allrightsreserved.机柜IT微环境北京仙络科技发展有限公司©SynclocCorporation.Allrightsreserved.•机柜与机架•RLU概念•机柜IT微环境•机柜IT微环境的监控内容简介©SynclocCorporation.Allrightsreserved.机架式服务器的发展趋势到2006年,66%的服务器将机架化WorldwideServerUnitShipmentForecastbyFormFactorWorldwideServerUnitShipmentForecastbyFormFactor01,000,0002,000,0003,000,0004,000,0005,000,0006,000,0007,000,0008,000,0009,000,000199619971998199920002001200220032004200520062007Non-Rack-optimizedRack-optimizedBladeUnits©SynclocCorporation.Allrightsreserved.•机柜与机架•RLU概念•机柜IT微环境•机柜IT微环境的监控内容简介©SynclocCorporation.Allrightsreserved.机柜与机架•封闭的为机柜,开放的为机架•通常不明确区分©SynclocCorporation.Allrightsreserved.服务器机柜与网络机柜•前后通风的为服务器机柜,前后不通风的为网络机柜•网孔门与玻璃门玻璃门网孔门©SynclocCorporation.Allrightsreserved.机柜制造标准•工业标准的19英寸A=FrontCabinetApertureB=Hole-to-HolepacingC=Panel/BezelAperture450mm[17.717”]minimum465mm[18.307”]nominal512mm[20.157”]minimum©SynclocCorporation.Allrightsreserved.•工业标准机架式设备的高度——U的概念机柜制造标准©SynclocCorporation.Allrightsreserved.标准19英寸服务器机柜前门设计:网孔后门:网孔,双开©SynclocCorporation.Allrightsreserved.顶部:预留线缆入口,方便上走线布局底部:预留线缆入口,方便下走线布局侧面:带布线通道,用于安装机架式PDU,并方便侧面线缆管理标准19英寸服务器机柜©SynclocCorporation.Allrightsreserved.•机柜•RLU概念•机柜IT微环境•机柜IT微环境的监控©SynclocCorporation.Allrightsreserved.RLU概念•机架化时代带来的变化--一切都“上架”了•不同IT的设备,无论是塔式服务器的上架。。。©SynclocCorporation.Allrightsreserved.RLU概念•。。。机架式服务器的上架。。。©SynclocCorporation.Allrightsreserved.RLU概念•。。。还是小型机(独立机柜)。。。©SynclocCorporation.Allrightsreserved.RLU概念•。。。各种设备的上架。。。©SynclocCorporation.Allrightsreserved.RLU概念•它们都有共同之处:–作为机房空间的单元出现–需要电源–需要制冷–占用空间–具有重量–需要连通性–需要安全性–具有运算、存储、传输能力©SynclocCorporation.Allrightsreserved.RLU概念•这样的机柜(机架),就是RLU–RackLocationUnit–机柜定位单元–包括•19”标准机柜•小型机专用机柜•21U机柜•42U机柜•等等©SynclocCorporation.Allrightsreserved.•机柜•RLU概念•机柜IT微环境•机柜IT微环境的监控内容简介©SynclocCorporation.Allrightsreserved.机柜IT微环境•IT微环境-为IT设备提供:–供电–制冷–空间–重量支撑–连通性需要–安全性需要©SynclocCorporation.Allrightsreserved.机房环境与IT微环境•机房环境-为RLU(IT微环境)提供:–供电–制冷–空间–重量支撑–连通性需要–安全性需要©SynclocCorporation.Allrightsreserved.IT微环境之供电--机架级配电PowerDistributionatRLULevel©SynclocCorporation.Allrightsreserved.机柜级配电常见问题©SynclocCorporation.Allrightsreserved.机柜级配电常见问题©SynclocCorporation.Allrightsreserved.机柜内的配电问题—双电源©SynclocCorporation.Allrightsreserved.机柜内的配电方案--PDU©SynclocCorporation.Allrightsreserved.什么是PDU?PDU(PowerDistributionUnit),即电源分配单元,为标准的机架级配电的标准模式。©SynclocCorporation.Allrightsreserved.标准电源适配器类型©SynclocCorporation.Allrightsreserved.•国标GB1002插头插座标准电源连接器©SynclocCorporation.Allrightsreserved.•IEC320--国际电工委员会连接器标准标准电源连接器IEC320C13插座IEC320C14插头IEC320C19插座IEC320C20插头©SynclocCorporation.Allrightsreserved.•NEMA(美标)CEE7/7(欧标)标准电源连接器5-15PDN49441©SynclocCorporation.Allrightsreserved.标准电源连接器•IEC309--国际电工委员会连接器标准•防溅插头,又称工业连接器•通常作为PDU输入连接方式©SynclocCorporation.Allrightsreserved.•机架式PDU机架配电方案©SynclocCorporation.Allrightsreserved.•机架式PDU机架配电方案©SynclocCorporation.Allrightsreserved.机架配电方案©SynclocCorporation.Allrightsreserved.•水平安装机架配电方案©SynclocCorporation.Allrightsreserved.•垂直安装机架配电方案©SynclocCorporation.Allrightsreserved.机架配电解决方案•PDU实例©SynclocCorporation.Allrightsreserved.•PDU的输入机架配电方案©SynclocCorporation.Allrightsreserved.机架配电方案•PDU的输入布线©SynclocCorporation.Allrightsreserved.•PDU安装、测试机架配电方案©SynclocCorporation.Allrightsreserved.IT微环境之制冷--机架级配风AirDistributionatRLULevel©SynclocCorporation.Allrightsreserved.ProblemKlimavonRaumundSchrank!1001.00010.000100.0001.000.00010.000.000100.000.00019721977198219871992199720022007NumberofTransistorsSpeedinkHz1001.00010.000100.0001.000.00010.000.000100.000.00019721977198219871992199720022007NumberofTransistorsSpeedinkHz问题:数据中心的散热当今,CPU的功耗已经达到了70-100W/cm2。这意味着一个服务器机柜的功耗相当于一张报纸大小的桑拿浴炉所产生的热量。刀片式服务器的发展更增强了这种趋势。甚至目前功率损耗达到了10千瓦!目前服务器机柜散热问题已经日益成为设计数据中心的最主要限制因素。目前的机房精密空调的冷风(从升高地板或从机房)不再足够。从物理角度考虑,通过空气流动只可从每台机柜带走3-4千瓦的热散耗。目前运行的数据中心受到空气冷却的限制,机柜有关的热区不断出现。这就要求结合机房和机柜冷却系统!©SynclocCorporation.Allrightsreserved.机柜功率的增加:•3-15KW•在某些区域达到20KW•机房的空调系统已不能应对这些热点©SynclocCorporation.Allrightsreserved.机架级配风方案1.使用盲板•适用场合:1-20KVA•用途:防止热空气在机架内循环(短路);提高冷量利用率©SynclocCorporation.Allrightsreserved.2.加装风扇机架级配风方案©SynclocCorporation.Allrightsreserved.•适用场合:1-3KVA;•用途:增加机柜内的配风量;引导排风方向机架级配风方案©SynclocCorporation.Allrightsreserved.•注意:顶部风扇?--不能解决机架式服务器的散热问题机架级配风方案©SynclocCorporation.Allrightsreserved.加装顶部风扇时机架内温度机架级配风方案©SynclocCorporation.Allrightsreserved.3.加装强制送风系统机架级配风方案©SynclocCorporation.Allrightsreserved.•适用场合:3-5KVA;高架地板;特殊机柜•用途:增加配风量机架级配风方案©SynclocCorporation.Allrightsreserved.•适用场合:3-5KVA;高架地板;特殊机柜•用途:增加配风量机架级配风方案©SynclocCorporation.Allrightsreserved.4.加装强制排风系统机架级配风方案©SynclocCorporation.Allrightsreserved.•适用场合:3-5KVA;无高架地板;侧送顶回•用途:隔离回风、减少短路机架级配风方案©SynclocCorporation.Allrightsreserved.•适用场合:3-5KVA;无高架地板;侧送顶回•用途:隔离回风、减少短路机架级配风方案©SynclocCorporation.Allrightsreserved.5.机柜区(群)级隔离系统–适用场合:1-20KVA–用途:隔离送回风;提高冷量利用率机架级配风方案©SynclocCorporation.Allrightsreserved.天花盖板系统侧门InfraStruXureHighDensity热通道封闭系统机架级配风方案©SynclocCorporation.Allrightsreserved.冷通道封闭系统天花盖板系统侧门(推拉门)机架级配风方案©SynclocCorporation.Allrightsreserved.IT微环境之承重WeightLoadatRLULevel©SynclocCorporation.Allrightsreserved.问题:机柜内设备重量IT设备的重量密度也在增加。平均每RU的重量,可达到20kg。这意味着整个机柜需要承重840kg。这很容易引起机柜的框架

1 / 66
下载文档,编辑使用

©2015-2020 m.777doc.com 三七文档.

备案号:鲁ICP备2024069028号-1 客服联系 QQ:2149211541

×
保存成功