客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)1内容:1.前言··································································22.总述··································································22.1菜单结构····························································22.2功能键······························································43.主菜单(测量值)——K1键················································53.1开炉·································································63.2停炉·································································63.3主菜单——K1键······················································64信息菜单——K4键······················································94.1报警·································································94.2事件·································································105控制器菜单——K5键···················································116运行时间菜单——K6键·················································127测试开关菜单——K7键·················································148系统菜单——K13键····················································158.1时间设定·························································168.2LBC版本菜单·····················································179故障诊断······························································19客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)21.前言这些操作指导包含一些基本信息,它们与下列操作指导一起应用:A002基本的安全指导H018C7-633自动装置作为一个操作系统,其中各个部件的操作指导要遵循当地相关的法律法规和政府规定。本操作指导书主要介绍操作程序和LBC的功能键。并描述了每台LOOS锅炉控制的基本功能。2.总述2.1菜单结构K1….K13,F1….F4键:按下这些键将带你进入下一级菜单,如下:客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)3客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)42.2功能键描述下面列出了所有的功能键,在某一个特定的系统中,将会根据用户的订货范围,决定哪些功能键有用。LBC的功能键具体说明如下:主界面(见第3点)燃烧器控制菜单(见操作指导G160~G165)给水泵控制菜单(见操作指导G120~G129)事件菜单(见第4点)控制器菜单(见第5点)客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)5运行时间菜单(见第6点)测试开关菜单(见第7点)自动排污菜单(见操作指导G153)燃料选择菜单(见操作指导G166~G175)操作模式菜单(见操作指导G190~G197)蒸汽阀菜单(见操作指导G80)排烟挡板控制菜单(见操作指导G176)系统菜单(见第8点)高水位显示(见操作指导G110—BAG115-LED显示)低水位显示(见操作指导G110—BAG115-LED显示)解除警报按钮3.主菜单-K1键如果无故障时,按下锅炉操作屏上K1键后,LBC显示屏上将显示主界面1(见图1)。在主界面里包含了锅炉运行的所有重要信息,而锅炉的启动参数设定必须由LOOS服务部门人员或者LOOS公司授权人员完成。可以通过主界面1启动和关断锅炉。程序如下:客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)63.1启动锅炉——如果锅炉系统无故障的话,按下“MAIN”键,LBC显示屏将显示主界面1(见图1);如果有故障的话见第4点。——按下功能键F2释放LBC的输入量和输出量信号(控制开关),该键一按下,星号(*ON*)就会出现。——用功能键K10预选操作模式,(选中的操作模式将出现在主界面上)。——用功能键F9预选燃料(选中的燃料将显示在主界面上,如果要保留该选择,不需做任何改变),对于双炉胆锅炉和单燃料锅炉,所选燃料将不会出现在主界面上。下一步程序要看状态显示或安全控制链的开关位置。FRKL:所有存在的控制链——负荷控制器除外——均在“自动”开关位置。可以利用功能键F3自动启动锅炉。F3键一被按下。星号(*AUTO*)就出现在主界面上。除了负荷控制器以外,所有控制在自动模式下运行,但锅炉停留在小火位置上运行。当锅炉从冷态启动时,对于分段比例调节燃烧器的大火和无级调载燃烧器,自动模式可以在“controllers”菜单(loadcontroller)中释放,从大约0.5bar时释放。负荷控制器(loadcontroller)模式一经修改,自动模式(AUTO)两旁的星号将消失。锅炉内的水位必须时刻监控,炉水由于热膨胀,一出现高水位预警,马上通过排污阀排锅炉内的水,直到报警消失为止。:控制链中最少一个控制量处于“MANUAL”(手动)位置(loadcontroller除外),自动启动即不可能。按下功能键F3,没有任何效果。只有当所有的控制量转到“AUTO”上(loadcontroller除外)时,FRKL才会显示在状态栏里。自动启动键F3此时才管用。:所有的控制量都处在(包括LOADCONTROLLER)“AUTO“的位置上。3.2停炉——在主界面1下按功能键F4,将使锅炉在受控方式下进入小火状态。同时“ABF“就在显示屏上闪烁。120后,燃烧器关断。所有的控制链——除了LOADCONTROLLER(负荷控制器)外——都保持在预设状态。负荷控制器在按下F4键关断燃烧器后自动设置到小火位置上。——用F1键(控制切断)将LBC输入量和输出量切断。一按下F1键,星号(*OFF*)即出现在显示屏上。3.3主菜单(测量值)-K1键如果无故障,按下LBC控制界面的K1键,或者锅炉控制柜主开关合上后,主界面1出现。客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)7单炉胆锅炉(SBF)主界面双炉胆锅炉(DFB)主界面图1主界面图2主界面显示量:第一行:右开关点位置显示“远程——本地“(REMOTE,LOCAL)第二行:左锅炉操作模式状态显示(正常模式,保温)中间控制链中所有的开关位置状态显示(AUTOMANUALFRKL)AUTO:所有控制链均处于“自动“位置MANUAL:最少一个控制链处于“手动“位置FRKL:所有控制链(除了负荷控制器外)均在“自动“状态下。右燃料选择第三行:P:当前锅炉压力值L:当前锅炉水位按下功能键时的响应:F1:停炉F2:启动锅炉F3:自动模式,启动锅炉F4:自动模式,停炉(“ABF”闪烁——状态:控制自动模式停止)说明:在主界面1按键(见图1和图2),将带你进入主界面菜单2-7-测量值(图3-12)。注意:以下给出了或关锅炉所有可能的测量值,功能包含不同客户订单所要的测量值的显示。如果传感器发出错误,或者订单中不包含的测量项目则“####”标记就会取代数字出现在显示屏上。测量值显示:双炉胆锅炉(DFB)单炉胆锅炉(SFB)图3:主界面2图4:主界面2客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)8图5:主界面3图6主界面3图7:主界面4图8:主界面4图9:主界面5图10:主界面5图11:主界面6图12:主界面7显示量:pressure:当前锅炉工作压力,单位barlevel:当前锅炉内水位,%conduct:当前表面炉水传导率,µs/cmT.wastegas:当前排烟温度,℃T.SHLEFT:当前左过热器温度,℃(如果是单炉胆锅炉,只显示一个过热器温度)客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)9T.SH.RIGHT:当前右过热器温度,℃(如果是单炉胆锅炉,只显示一个过热器温度)LoadBurnerL:左燃烧器当前负荷,%(如果是单炉胆锅炉,只显示一个负荷值)LoadBurnerR:右燃烧器当前负荷,%(如果是单炉胆锅炉,只显示一个负荷值)OilQu.L:左燃烧器当前燃油量l/h(单炉胆锅炉只显示一个燃油量)OilQu.R:右燃烧器当前燃油量l/h(单炉胆锅炉只显示一个燃油量)GasQu.L:左燃烧器当前燃气量m3/h(单炉胆锅炉只显示一个燃气量)GasQu.R:右燃烧器当前燃气量m3/h(单炉胆锅炉只显示一个燃气量)St.Quant.:当前蒸汽量t/hF.W.Quant.:当前给水量m3/hFeedW.Valve:当前给水电动阀位置%说明:在主界面按下键将带1你进入下一级界面,而按键将带你返回上一级界面。4.事件菜单按功能键K4转到“message”菜单中的主界面1(见图13)图13开始界面1按下功能键时的反应:F1:查看报警情况(见4.1点)F2:参看历史事件(见4.2点)4.1报警报警一出现,就会在显示屏上闪烁显示一个文字形式说明的故障,同时,红色的报警LED灯也开始闪烁,按下黄色的“ACK”键,即可获知当前的报警信息。如果所有的报警都已获悉,但是故障原因还没有被排除,闪烁的LED灯也将转变成一个稳定发光的红灯。如果有几个报警,可以连续按下“ESC”键一个一个查看,如果有必要可以利用箭头键(和)上下翻看。客户服务技术手册LOOS锅炉控制(LBC)G100Version1(12/01)10由错误引起的锅炉控制系统故障由一个连续的喇叭报警提醒。按K16键可消除警报声,但错误仍然存在。错误没有导致锅炉控制故障的话,就只是以一个不间断的喇叭报警声提醒。在第9点列出了所有的报警情况。所有报警均记录在报警存储器中,有“发生”“排除”和“接收时间”报警存储器最大可以存储256条信息。如果报警存储器已满,当出现新报警时,最早的记录将被覆盖。这个存储器资料可以在“message”菜单里按F1键查看。(见图13)。记录事件的格式如下:图14图15每条事件的详细内容(图15)可以通过按键查看,按键回到图14菜单。例:“来”报警:Ack-Gr/No.00/011A“箭头键”011code11On19.07.0110:58:46Disturbancefeedwaterpump“去”报警:Ack-Gr/No.00/011D“箭头键”011code11On19.07.0110:58:46Disturbancefeedwaterpump确认输入:Ack-Gr/No.00/010Q“箭头键”011code11On19.07.0111:05:43Disturbancefeedwaterpum